Contents
The FCC Wants You To Know ...................................................................................................................1
Scanning Legally ........................................................................................................................................2
Introduction .................................................................................................................................................3
Using this Manual ...................................................................................................................................5
Understanding Scanning ............................................................................................................................6
Conventional Scanning ...........................................................................................................................6
Simplex Operation ..............................................................................................................................6
Repeater Operation ............................................................................................................................6
Trunked Scanning ..................................................................................................................................7
Motorola Trunking ...............................................................................................................................7
EDACS Trunking ................................................................................................................................8
LTR Trunking ......................................................................................................................................9
Understanding Banks and Channels ......................................................................................................9
Getting More Information .........................................................................................................................10
Front and Rear View ................................................................................................................................11
Display Icons ........................................................................................................................................12
Included With Your Scanner ....................................................................................................................13
Setting Up Your Scanner .........................................................................................................................14
Connecting an Antenna ........................................................................................................................14
Mounting an Antenna ...........................................................................................................................14
Optional Antenna ..................................................................................................................................14
Typical Mounting Methods ...................................................................................................................15
Mounting the Scanner in Your Vehicle .................................................................................................15
Applying Power for Vehicle Installation ................................................................................................16
Desktop Installation ..............................................................................................................................17
Applying Power Using Standard AC Power .........................................................................................17
Connecting an External Speaker ..........................................................................................................17
Connecting an Earphone ......................................................................................................................17
Listening Safely ....................................................................................................................................18
Connecting the Clone Cable ................................................................................................................18
Connecting the Tape Recorder ............................................................................................................18
Basic Operation ........................................................................................................................................19
Turning On the Scanner .......................................................................................................................19
Setting the Squelch ..............................................................................................................................19
Using the Menu ....................................................................................................................................20
Manually Selecting a Channel ..............................................................................................................20
Scanning Programmed Channels ........................................................................................................20
Locking/Unlocking Banks .....................................................................................................................20
Locking/Unlocking Channels ................................................................................................................21
Restoring All Locked Out Channels .....................................................................................................21
Priority Scanning ..................................................................................................................................21
Priority Plus Scanning ..........................................................................................................................21
Listening to the Input Channel .............................................................................................................21
Dimmer Light Setting ............................................................................................................................22
Controlling How Much Information Appears .........................................................................................22
Turning the Key Beep On/Off ...............................................................................................................22
Locking the ENTER key .......................................................................................................................22
Disabling the APCO25 Card .................................................................................................................23
Muting All Audio ...................................................................................................................................23
Setting Squelch Mode ..........................................................................................................................23
Trunk Scanning Options .......................................................................................................................23
Searching for Active Talkgroups (ID Search) ...................................................................................23
Scanning Only Stored Talkgroups (ID Scan) ...................................................................................24
Monitoring Talkgroup ID’s .................................................................................................................24
Selecting Talkgroup Lists to Scan ....................................................................................................24
Holding on a Single Talkgroup .........................................................................................................24
Locking Out Talkgroups ....................................................................................................................24
EDACS Blockout ...............................................................................................................................25
Unlocking All Talkgroups ..................................................................................................................25
EDACS Patch Tracking ....................................................................................................................25
Searching .................................................................................................................................................26
Holding on an Active Frequency ..........................................................................................................26
Setting Chain Search ...........................................................................................................................26
Setting Data Skip ..................................................................................................................................26
Skipping Frequencies ...........................................................................................................................26
Storing Found Frequencies ..................................................................................................................27
Automatically Storing Frequencies .......................................................................................................27
Setting Subaudible Tones for Searching ..............................................................................................28
Searching for Subaudible Tones ..........................................................................................................28
Attenuating All Search Ranges ............................................................................................................28
Setting DELAY for All Search Ranges .................................................................................................28
Setting a Search Range .......................................................................................................................29
Searching for Trunk Systems ...............................................................................................................29
Service Search .........................................................................................................................................31
Service Search Skip .............................................................................................................................31
Using Weather Search and Weather Alert (SAME) .............................................................................32
Searching for a Weather Broadcast .................................................................................................32
Using Weather Alert (SAME) ............................................................................................................32
Testing the Weather Alert .................................................................................................................33
Programming Bank Information ...............................................................................................................34
Bank Configuration ...............................................................................................................................34
Assigning Bank Names ........................................................................................................................34
General Programming ..............................................................................................................................35
Deleting Frequencies from Channels ...................................................................................................35
Transferring Channel Information .........................................................................................................35
Entering Alpha Information ...................................................................................................................35
General Programming Tips ..................................................................................................................35
Programming Conventional Channels .....................................................................................................37
1. Select a Channel to Program ...........................................................................................................37
2. Enter the Frequency .........................................................................................................................37
3. Assigning a Text Tag .......................................................................................................................37
Setting the Delay ..................................................................................................................................38
Setting the Subaudible Tone Option ....................................................................................................38
Setting Beep Alert ................................................................................................................................39
Setting the Attenuator ...........................................................................................................................39
Changing the Frequency Step ..............................................................................................................39
Setting the Modulation Mode ................................................................................................................40
Setting Priority Channels ......................................................................................................................40
Programming Trunked Systems ...............................................................................................................41
Setting Trunking Delay .........................................................................................................................42
Using I-Call (Motorola and EDACS only) .............................................................................................42
Turning I-Call On and Off for ID Search ...........................................................................................42
Turning I-Call On for ID Scan ...........................................................................................................42
Setting Priority Talkgroups (Motorola and EDACS only) .....................................................................43
Multi-Track ............................................................................................................................................43
Multi-Track Operational Details ........................................................................................................43
Programming Motorola Systems ..............................................................................................................45
Using Control Channel Programming ...................................................................................................45
Programming Type 2/Digital 800 and 900 MHz Systems ....................................................................45
Programming Type2/Digital VHF and UHF Systems ...........................................................................46
Programming Type I and IIi Hybrid Systems .......................................................................................47
Toggling the Status Bit .........................................................................................................................48
Toggling End Code Detect ...................................................................................................................48
Programming EDACS Systems ...............................................................................................................49
Programming EDACS Channels ..........................................................................................................49
Setting EDACS Emergency Alert .........................................................................................................49
Setting EDACS Decimal Mode .............................................................................................................50
Programming APCO 25 Systems .............................................................................................................51
Setting APCO 25 Sound Quality ..........................................................................................................51
Programming LTR Systems .....................................................................................................................52
Programming Talkgroups .........................................................................................................................53
Storing Known Talkgroups ...................................................................................................................53
Storing Found Talkgroups ....................................................................................................................53
Deleting Stored Talkgroup ID’s ............................................................................................................54
Adding a Text Tag to an ID List ...........................................................................................................54
Seeing Talkgroup Activity .....................................................................................................................54
Using the Remote Interface .....................................................................................................................55
PC Control Mode ..................................................................................................................................55
Cloning Scanner Settings .....................................................................................................................55
Care and Maintenance .............................................................................................................................57
General Use .........................................................................................................................................57
Location ................................................................................................................................................57
Cleaning ...............................................................................................................................................57
Repairs .................................................................................................................................................57
Birdies ...................................................................................................................................................57
Troubleshooting.........................................................................................................................................58
Specifications ............................................................................................................................................60
Glossary of Terms ....................................................................................................................................61
Appendix ..................................................................................................................................................64
One Year Limited Warranty ......................................................................................................................74
The FCC Wants You To Know
This scanner has been tested and found to comply with the limits for a scanning receiver,
pursuant to Part 15 of FCC rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This scanner generates, uses, and
can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this scanner does cause harmful interference to radio or television reception, which can be
determined by turning the scanner on and off, you are encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the scanner and the receiver
This device complies with Part 15 of FCC rules. Operation is subject to the following two
conditions: 1) This device may not cause harmful interference, and 2) this device must
accept any interference received, including interference that may cause undesired operation.
1
Scanning Legally
Your scanner covers frequencies used by many different groups, including police and fire
departments, ambulance services, government agencies, private companies, amateur radio
services, military operations, pager services, and wire line (telephone and telegraph) service
providers. It is legal to listen to almost every transmission your scanner can receive.
However, there are some transmissions that you should never intentionally listen to. These
include:
• Telephone conversations (cellular, cordless, or other private means of telephone signal
transmission)
• Pager transmissions
• Any scrambled or encrypted transmissions
According to the Electronic Communications Privacy Act (ECPA), you are subject to fines
and possible imprisonment for intentionally listening to, using, or divulging the contents of
such a conversation unless you have the consent of a party to the conversation (unless such
activity is otherwise illegal).
This scanner has been designed to prevent the reception of cellular telephone transmissions
and the decoding of scrambled transmissions. This is done to comply with the legal
requirement that scanners be manufactured so they are not easy to modify to pick up these
transmissions. Do not open your scanner’s case to make any modifications that could allow
it to pick up transmissions that are illegal to monitor. Modifying or tampering with your
scanner’s internal components or using it in a way other than as described in this manual
could invalidate your warranty and void your FCC authorization to operate it.
In some areas, mobile use of this scanner is unlawful or requires a permit. Check the laws in
your area. It is also illegal in many areas (and a bad idea everywhere) to interfere with the
duties of public safety officials by traveling to the scene of an incident without authorization.
®
®
Uniden and Bearcat are registered trademarks of Uniden America Corporation.
TrunkTracker is a proprietary trademark of Uniden America Corporation.
Other trademarks used throughout this manual are the property of their respective holders.
2
Introduction
The BC796D APCO 25 Digital Trunking Scanner connects you to the exciting world of
scanning. Capable of scanning conventional frequencies, analog trunking systems, and the
most popular digital trunking systems, it is a great all-in-one solution to your scanning needs.
Here is a brief list of some of the systems you can monitor with your BC796D:
• Motorola Type I, II, IIi Hybrid, and APCO 25 Phase 1 Digital Systems (including 3600 bps
and 9600 bps control channel systems) EDACS and EDACS SCAT trunking systems used
by police, fire, ambulance, and other local and state public safety agencies as well as utili-
ties and other businesses.
• LTR trunking systems used by local businesses and a few public safety agencies.
• Conventional Digital APCO 25 frequencies
• CB, GMRS, FRS, Marine, and other 2-way radios used by families, truckers, and commu-
nity groups
• Business Band frequencies used nationwide
• Amateur Radio frequencies used by licensed radio operators to report emergency weather
conditions, experiment with new communications methods, or just to chat.
• Local and national government agencies
• Civil and military aircraft
• FM and TV Broadcast channels
• NOAA Weather Radio
• And much, much more!
The table below lists the frequency ranges, the default mode (AM, FM, or Wideband FM),
and the default frequency step for each range.
Mode Step
(MHz) (kHz)
Mode Step
(MHz) (kHz)
Frequency Range
Frequency Range
25.0000 - 27.9950
28.0000 - 53.9900
54.0000 - 71.9500
72.0000 - 75.9950
76.0000 - 87.9500
88.0000 - 107.9000
108.0000 - 136.9750
137.0000 - 161.9950
162.0000 - 173.9875
AM
FM
WFM 50
FM
WFM 50
WFM 100
AM
FM
5
10
174.0000 - 215.9500
216.0000 - 224.9950
225.0000 - 399.9500
400.0000 - 512.0000
806.0000 - 823.9875
849.0125 - 868.9875
894.0125 - 956.0000
WFM 50
FM
AM
5
50
5
NFM 12.5
NFM 12.5
NFM 12.5
NFM 12.5
25
5
1240.0000 - 1300.0000 NFM 12.5
FM 12.5
3
In addition, here are a few more of the many features your scanner has. To get the most
from your scanner, be sure to review this entire manual.
• APCO Project 25 Phase 1 Compatible – works on the latest 9600 bps systems, including
systems that use C4FM and CQPSK modulation.*
• Four-line, 16-character, Alpha Display – makes it easy for you to see who is talking by
displaying the assigned text tag instead of just a frequency or talkgroup ID number.
• Automatic Digital Detect – allows the scanner to switch to digital voice decoding when it
detects valid APCO 25 data without any special programming.
• 1000 Channels – lets you store frequencies in 10 banks of 100 channels each.
• 1000 Talkgroup ID’s – lets you store 10 groups of 10 ID’s each per bank.
• Multi-System Tracking – scans conventional and trunking systems at the same time.
• Included PC Programming Software and Cable – makes programming your scanner
much easier. Full-featured software included (no registration needed).
• 10 Priority Channels – switches to the channel you assign as priority if there is activity,
so you won’t miss a thing.
• Priority Talkgroups – increases the priority of selected talkgroups so the scanner is more
likely to switch to them if there is activity.
• Priority Plus Scanning – lets you scan only those channels you have selected as priority
channels.
• CTCSS and DCS Squelch Modes – prevents interference from stations not using the
mode you select; search mode displays the CTCSS or DCS tone being used by the
received station.
• Preprogrammed Service Search – makes it easy to find interesting frequencies used by
public safety, news media, TV broadcast, weather, amateur radio, FRS, GMRS, special
low power, railroad, aircraft, marine, and racing services.
• Data Skip – automatically skips frequencies that have a constant-level transmission such
as used on data channels for some systems, paging systems, and internally generated
birdies.
• SAME Weather Alert with FIPS – lets you set your scanner to listen for a SAME event
code from the local weather service; sounds an alert and displays the text description for
any alert received. FIPS programming lets you restrict the alerts to one county.
• Turbo Search – searches for activity on frequencies at up to 300 steps per second (in the
5 kHz step ranges).
• Scanner Clone Mode – lets you connect your scanner directly to another scanner to
clone all channels and settings.
*Note: Performance on digital systems can vary due to signal quality, multipath interference, and cellular
interference. Unlike analog trunking, where you can hear the audio with some interference mixed in,
interference in a digital system completely blocks the signal. If you do not get good digital reception, try
adjusting your location or your antenna until reception improves.
4
Using this Manual
To get the most from this manual, review the contents to become familiar with the basic
functions available. If you are new to scanning or trunktracking, be sure to read the
“Understanding Scanning” section for a quick background on the technology behind the
hobby.
The first thing you’ll need to do is plug the AC charger into the scanner. See “Setting Up
Your Scanner” if you need any help doing this.
Next, you’ll want to listen to see what you can hear with your scanner. Install the antenna,
then press SRVC and use the scroll bar to select TV Broadcast. Assuming you are in an
area with a strong enough TV broadcast, your scanner should soon stop on a station’s audio
program. Listen to this, or try searching another service for something more interesting,
while you review the rest of the manual.
5
Understanding Scanning
This section provides you with the background on how scanning works. You don’t really
need to know all of this to use your scanner, but some background knowledge will help you
to get the most from your BC796D.
Conventional Scanning
Conventional scanning is a relatively simple concept. Each group of users in a conventional
system is assigned a single frequency (for simplex systems) or two frequencies (for repeater
systems) to use. Any time one of them transmits, their transmission always goes out on the
same frequency. Up until the late 1980’s this was the primary way that radio systems
operated. Even today, there are a lot of 2-way radio users who operate using a conventional
system:
• Aircraft
• Amateur Radio
• FRS/GMRS Users
• Broadcast AM/FM/TV Stations
• Many Business Radio users
When you want to store a conventional system, all you need to know is the frequency they
operate on.
When you are scanning a conventional system, the scanner stops very briefly on each
channel to see if there is activity. If there isn’t, the scanner quickly moves to the next
channel. If there is, then the scanner pauses on the transmission until it is over.
Simplex Operation
Simplex systems use a single frequency for both transmit and receive. Most radios using this
type of operation are limited to line-of-sight operation. This type of radio is frequently used at
construction job sites, and with inexpensive consumer radios such as GMRS/FRS radios.
The range is typically 1-5 miles, depending upon the terrain and many other factors.
Repeater Operation
Repeater systems use two frequencies: one transmits from the radio to a central repeater;
the other transmits from the repeater to other radios in the system. With a repeater based
system, the repeater is located on top of a tall building or on a radio tower that provides
great visibility to the area of operation. When a user transmits (on an input frequency), the
signal is picked up by the repeater and retransmitted (on an output frequency). The user’s
radios always listen for activity on the output frequency and transmit on the input frequency.
Since the repeater is located very high, there is a very large line of sight. Typical repeater
systems provide coverage out to about a 25 mile radius from the repeater location.
6
Trunked Scanning
While conventional scanning worked great while there were only a few groups wanting to
use the frequencies, with the advent of smaller, lower-cost radios more and more agencies
and businesses wanted to take advantage of the utility of 2-way radio. As a result, the bands
that were used most became full, so new users were not able to take advantage of the
technology as quickly as they wanted.
Trunking solved this frequency shortage by allowing multiple groups to use the same set of
frequencies in a very efficient way. While each type of trunking system operates a little
differently (see the next few sections), they all work on the same basic premise: even in a
system with a lot of users, only a few users are ever transmitting at any one time.
Instead of being assigned a frequency, as with conventional systems, each group is
assigned a Talkgroup ID. A central computer controls the frequency each group operates
on...and this frequency selection is made each time a user transmits. So, while on a
conventional system queries, replies, and follow-ups are all on a single frequency, they
could each be on completely different frequencies on a trunked system. This semi-random
frequency assignment made monitoring such a system impossible prior to Uniden’s invention
of the Trunktracking scanner.
Motorola Trunking
While there are 4 different types of Motorola trunking systems, they all use the same basic
trunking method. The system consists of one control channel plus one or more voice
channels (typically 10, 20, or 30 total channels). When a user presses Push To Talk (PTT)
to transmit, their radio first sends their talkgroup information to the control channel. The
computer then assigns that talkgroup to a specific voice channel and transmits that data
over the control channel. All radios in that talkgroup switch over to the assigned voice
channel and the user can begin speaking. This all typically takes place in about a
second...the person transmitting hears a beep from their radio when the channel is assigned
and it is OK to start talking.
The four systems in use are:
• Motorola Type I – the radios send the radio ID, the fleet and subfleet talkgroup ID to the
control channel each time they transmit. To program a Type I system, you need to know
the system’s fleet map. The most common fleet maps are included at the back of this
manual. You can also find fleet map resources on the web.
• Motorola Type II – the radios only send the radio ID and radio channel code to the control
channel. The central computer keeps a database of radio ID’s and which talkgroup is
assigned to which channel code for each radio, so with this system the user’s radio sends
only about 1/3 the data as a Type I system with each transmission. Type II systems do not
use Fleet-subfleet talkgroups; instead they use a 5-digit ID for each talkgroup.
• Type IIi Hybrid — these systems support a mix of both Type I and Type II users. Like
Type I systems, you must know the system’s fleetmap to ensure proper tracking.
• Motorola Astro Digital — for channel control purposes, this type of system operates just
like a Type II system — although the control channel can be a 3600 bps data rate (for
mixed analog/digital systems) or a 9600 bps (for digital-only systems). Pure digital sys-
tems can be implemented under APCO 25 Phase 1 or Phase 2 standards. Your BC796D
is able to decode all unencrypted digitized voice traffic on either mixed mode or digital-only
APCO 25 Phase 1 systems.
7
One big difference you will notice with digital versus analog transmissions, is that with
analog systems, you might be able to hear weak signals interspersed with hissing. As you
move further away from the system, the interference gradually increases until you are
unable to make out the transmission. With digital systems, the cutoff point is much more
abrupt. You might have a small area where partial decoding occurs...in which case you will
hear partial and garbled audio. However, once the scanner is unable to receive the data well
enough to decode it, the audio stops entirely. For the best range, antenna selection and
placement is critical. See “Connecting an Antenna” for more information.
EDACS Trunking
EDACS trunking works in much the same way as Motorola trunking with a couple of major
differences. In an EDACS system, each frequency used by the system is assigned a Logical
Channel Number (LCN) so that less data needs to be transmitted by the control channel.
Also, talkgroups are assigned in an Agency-Fleet-Subfleet (AFS) hierarchy. Also, there is
one variation of EDACS called SCAT that your BC796D can monitor.
• Logical Channel Numbers – each frequency used by the system is assigned an LCN.
This information is programmed into each user radio. When a user presses PTT, their
radio sends their AFS information to the control channel. The computer then assigns that
talkgroup to a channel and sends the LCN so that all other radios in that talkgroup will
switch to the correct channel. To program a EDACS system in your scanner, you will need
to know both the frequencies used by the system and the LCN for each frequency so that
you can program the frequencies in LCN order.
• Agency-Fleet-Subfleet – talkgroup ID’s for EDACS systems are assigned in a way that
makes it easy to see at a glance the affiliation of the user. Each radio is assigned a 2-digit
agency identifier from 00 – 15. For example, 01 might be used by the police, 02 by
ambulance service, 03 by the fire department, and so on. Each agency is then subdivided
up to 16 times to provide fleet identification, and then 8 more times to identify subfleets.
For example, the complete AFS for the Police Department West District’s dispatch channel
might be 01-062. 01 identifies the agency as the police department, 06 identifies the fleet
as the West district, and 02 identifies the subfleet as the dispatch channel. While these
assignments are somewhat arbitrary and vary from system to system, there are many
resources on the web for finding the assignments for most systems.
Because of the logical hierarchy of the AFS system, your BC796D lets you assign wildcard
ID’s that let you, for example, use only one ID memory to identify all units in either an
agency or a fleet.
• EDACS SCAT – EDACS SCAT (Single Channel Autonomous Trunking) systems operate
on a single channel and alternate control data with analog voice traffic. While your
BC796D cannot track ID’s in this system, it can eliminate the control data so that all you
hear is the voice transmissions when you monitor this type of system.
8
LTR Trunking
®
LTR (Logic Trunked Radio) systems are trunking systems used primarily by business or
private communications service providers, such as taxicabs, delivery trucks, and repair
services. These systems encode all control information as digital subaudible data that
accompanies each transmission, so there is no separate control channel. Users on an LTR
system are assigned to specific talkgroups, which are identified by the radio as six digit
numbers. These numbers are in the form AHHUUU, where:
A= Area code (0 or 1)
H= Home repeater (01 through 20)
U= User ID (000 through 254)
When the scanner receives a transmission on a channel set to the LTR mode, it first
decodes the LTR data included with the transmission. In the ID Search mode, the scanner
stops on the transmission and displays the talkgroup ID on the display. In the ID Scan mode,
the scanner only stops on the transmission if the LTR data matches a talkgroup ID that you
have stored in the bank’s talkgroup ID list and have not locked out.
LTR systems are frequently programmed so that each radio has a unique User ID.
LTR systems also need to be programmed into your scanner in channel-order.
Since many LTR systems use only odd-numbered channel slots, you would program these
systems using only the corresponding odd-numbered channels in a bank (for example, you
would program a system with channels at 1, 3, 5, and 9 into Trunk 2 channels 101, 103,
105, and 109).
Understanding Banks and Channels
The memory in your scanner is organized into 10 banks of 100 channels each. Each bank
can contain conventional channels as well as 1 trunking system. For each trunking system,
each bank can also store 10 groups of 10 talkgroup ID’s (100 per bank).
9
Getting More Information
By itself, this manual really only provides part of what you need to know to have fun
scanning – how to program and use the scanner. The two supplied Conventional and
Trunking frequency guides will give you a good head start on the other part of what you
need to know – what frequencies have interesting content. You can also find a wealth of
information on the Internet...check out scanners.uniden.com for the latest frequency
information in your area.
In addition, you can contact the following source of frequency information:
• Scanner Master
(800) 722-6701 (Hours are from 10:00 a.m. to 5:00 p.m. Eastern Time Monday through
Friday.)
To purchase another copy of the conventional or trunking frequency guide, contact one of
the following:
• Uniden Parts Department
(800) 554-3988 (Hours are from 8:00 a.m. to 5:00 p.m. Central Time Monday through
Friday.)
• Your Local Dealer
10
Front and Rear View
3
4
5
6
7
8
VOLUME
1-100
101-200
401-500
701-800
901-1000
201-300
501-600
801-900
SELECT
MANUAL
HOLD
1
4
7
2
5
8
3
6
9
E
SCAN
SRVC
SRCH
301-400
601-700
RVRS
1
2
RSM
SQUELCH
CHAN/FREQ
LIMIT
0
MENU
TRUNK
1000
BC796D
L/O
PRI
TRNFR
MUTE
CHANNEL
BACK
VFO/SELECT PUSH
9
10
11 121314 15 16 17
1. Volume/Squelch Control
2. VFO/Select
Channel/Frequency Control
3. Scan Key (SCAN)
10. Search Key (SRCH)
11. Limit/Down Key (LIMIT/▼)
12. Trunk Key (TRUNK)
13. Decimal/Reverse Key
4. Service Key (SRVC)
(
)
5. Display
6. Resume Key (
14. Lockout Key (L/O)
15. Priority Key (PRI)
RSM
)
7. Hold/Up/Manual Key (▲/HOLD)
8. Numeric Keypad
9. Menu/Bank Key (MENU)
16. Transfer/Mute Key (TRNFR)
17. Enter/Select Key (E)
18
19
20 21
22
EXPANSION SLOT
23
20. External Speaker Jack
21. DC Power Jack
18. Antenna Connector
19. Tape Recorder Output Jack
22. Remote Control Terminal
23. Expansion Slot
11
Display Icons
ICON
DESCRIPTION
Priority Channel Indicator
P
L
/
Lock Out Mode Indicator
Scan/Search Direction Indicator
Chain Search Mode Indicator
Service Search Mode Indicator
Scan Mode Indicator
O
SRCH
SRVC
SCAN
ID SCAN
ID SEARCH
C
ID Scan Mode Indicator
ID Search Mode Indicator
Channel Type
Conventional Type
Trunk Type
M
L
E
Motorola Tracking Type
LTR Tracking Type
EDACS Tracking Type
DAT
LNK
Control Channel Data
Voice Channel Data
Digital Communications
P25: APCO Project 25
P25
AM,FM
WFM,NFM
Receiving Mode Indicators
Signal Meter
12
Included With Your Scanner
If any of these items are missing or damaged, immediately contact your place of purchase or
Uniden Customer Service at: (800) 297-1023, 8:00 a.m. to 5:00 p.m., Central Time, Monday
through Friday.
• BC796D Scanner
• AC Adapter (AD 580D)
• Cigarette Cord
• DC Cord
• Mounting Bracket
• Telescopic Antenna
• Operating Guide
• Trunk Tracker Frequency Guide
• Other Printed Material
• BC796D SS CD-ROM
13
Setting Up Your Scanner
Connecting an Antenna
You must install an antenna before you can operate the scanner. You have been provided a
standard telescopic antenna that works well with this scanner, but you may want to
purchases another type to increase the range. To connect the telescopic antenna, simply
connect it to the BNC type ANT. connector on the rear of the scanner. You can purchase a
variety of scanner antennas for both mobile and base station available at a local electronics
store. Choose the one that best meets your needs.
When deciding on a mobile or base station antenna and its location, consider these points.
• The antenna should be as high as possible on a vehicle or a house.
• The antenna and its cable should be as far as possible from sources of electrical noise
(ignition systems, gauges, and so on).
• The antenna should be vertical for the best performance.
Mounting an Antenna
Once you choose an antenna, follow the mounting instructions supplied with the antenna.
Then route the antenna cable to the scanner.
The antenna connector on your scanner makes it easy to use the scanner with a variety of
antennas, such as an external mobile antenna or an outdoor base station antenna.
Always use 50 ohm coaxial cable, such as RG-58 or RG-8, to connect an outdoor antenna.
For lengths over 50 feet, use RG-8 low-loss dielectric coaxial cable If your antenna’s cable
does not have a BNC connector, you will also need a BNC adapter (available at a local
electronics store).
Follow the Installation instructions supplied with the antenna, route the antenna cable to the
scanner, then connect it to the ANT. jack.
Warning: Use extreme caution when you install or remove an outdoor antenna. If the
antenna starts to fall, let it go! It could contact overhead power lines. If the
antenna touches a power line, contact with the antenna, mast, cable, or guy
wires can cause electrocution and death. Call the power company to remove
the antenna. DO NOT attempt to do it yourself.
Optional Antenna
If you have chosen an optional mobile antenna, connect the antenna plug into the ANT.
connector on the rear of the scanner. (For more information on antenna installation, please
refer to the instruction guide that came with your antenna.)
14
Typical Mounting Methods
The BC796D can be conveniently mounted on a table, bulkhead, overhead, or any other
desired location (refer to figure below for typical mounting methods).
Caution: Make sure there are no hidden electrical wires or other items behind the desired
location before proceeding. Check that free access for mounting and cabling
is available.
• Table top mount
• Bulkhead mount
• Overhead mount
Mounting the Scanner in Your Vehicle
Before you mount the scanner, make sure you have all the necessary materials. Then confirm
that the scanner fits your vehicle’s mounting area. This unit requires a mounting area of 2-3/8
inch high by 6-15/16 inch wide by 6-9/16 inch deep (61 x 176.5 x 167 mm).
Caution: Be sure to avoid obstructions behind the mounting surface.
Follow these steps to mount the scanner in your vehicle.
1. Choose a mounting location, then use the supplied
mounting bracket as a template to mark the positions for
the mounting screw holes.
2. In the marked positions, drill holes slightly smaller than
the supplied screws.
3. Attach the mounting bracket to the mounting location
using the supplied screws and lock washers.
4. Attach the scanner to the mounting bracket using the
supplied mounting knobs.
5. Connect the antenna’s cable to the ANT. connector on
the back of the scanner.
Note: If the antenna cable’s connector does not fit in the ANT.
connector, you might also need a Motorola-to BNC
antenna plug adapter (available at a local
electronics store).
15
Applying Power for Vehicle Installation
You can power your scanner using either the supplied DC power cord or your vehicle’s
cigarette lighter socket using DC cigarette lighter power cord.
Caution: You must use a power source that supplies 13.8 V DC and delivers at least
700 mA. Your standard 12 V car battery should be sufficient. The cord
connector’s center tip must be set to positive and its plug must fit the scanner’s
DC 13.8 V jack. The supplied DC power cord meets these specifications. Using a
power cord that does not meet these specifications could damage the scanner or
the adapter.
• Always connect the adapter or DC power cord to the scanner before you connect it to the
power source. When you finish, disconnect the adapter or DC power cord from the power
source before you disconnect it from the scanner.
• For added safety and to protect your scanner,
disconnect the cable from your vehicle battery’s
negative (-) terminal before you begin.
Follow these steps to connect the supplied DC power cord.
1. Connect the power cord’s black wire to a chassis ground, such
as a metal screw attached to a metal part of the vehicle’s frame. Be sure that the screw
is not insulated from the frame by a plastic part.
2. Connect the power cord’s red wire (with in-line fuse) to a source
of voltage that turns on and off with the ignition switch, such as
a spare accessory terminal in your vehicle’s fuse box.
3. Insert the power cord’s barrel plug into the DC 13.8 V jack
on the back of the scanner.
4. Reconnect the cable to the vehicle battery’s negative (-)
terminal.
To power the scanner from a vehicle’s 12 V power source
(such as a cigarette-lighter socket), you need a cigarette-lighter
adapter.
To connect an optional DC cigarette-lighter power cable, insert
its barrel plug into the DC 13.8 V jack on the back of the scanner, then plug the power cable
into your vehicle’s cigarette lighter socket.
Note: If you use a cigarette-lighter power cable and your vehicle’s engine is running, you
might hear electrical noise from the engine while scanning. This is normal.
16
Desktop Installation
You can place this scanner on a desk, shelf, or table to use it as a base station.
1. Flip up the feet for desk installation.
2. Extend the antenna to full vertical position.
Adjust the angle for best reception.
Applying Power Using Standard AC Power
To power the scanner from an AC outlet, use the provided AC
adapter with a 5.5 mm outer diameter/2.1mm inner diameter tip.
Caution: You must use a Class 2 power source that supplies 13.8 V DC and delivers at
least 700 mA. The cord connector’s center tip must be set to positive and its plug
must fit the scanner’s DC 13.8 V jack. Using an adapter that does not meet these
specifications could damage the scanner or the adapter.
• Always connect the AC adapter to the scanner before you connect it to AC power. When
you finish, disconnect the adapter from the AC power before you disconnect it from
the scanner.
1. Insert the adapter’s barrel plug into the DC
13.8 V jack on the back of the scanner.
2. Plug the adapter into a standard AC outlet.
Note: Use only the AC adapter supplied with
your scanner.
13.8V
Connecting an External Speaker
In a noisy area, an external speaker (available
at a local electronics store) positioned in the
right place might provide more comfortable
listening.
Plug the speaker cable’s 1/8 inch (3.5 mm) plug into your scanner’s EXT. SP. jack.
Note: Connecting an external speaker
disconnects the scanner’s
internal speaker.
Connecting an Earphone
For private listening, you can connect an
earphone with a 1/8 inch (3.5 mm) plug to the
EXT. SP. jack on the back of the scanner. Be very careful as damage to your hearing
can result if the VOLUME control is not set to the lowest level first. See below for
"Listening Safely" instructions. (Your local electronics store should carry a wide selection of
earphones.) Once the earphone is connected, it will automatically disconnects the internal
speaker.
17
Listening Safely
To protect your hearing, follow these guidelines when you use an earphone or headphones.
• Do not use the earphone to listen to the WX alert siren test or when in SAME Alert
mode. The alert tone's volume is not adjustable and damage to your hearing could
occur.
• Do not listen at extremely high volume levels. Extended high volume listening can lead to
permanent hearing loss.
• Set the VOLUME to the lowest setting before you begin listening. After you begin listening,
adjust the VOLUME to a comfortable level.
• Once you set the VOLUME, do not increase it. Over time, your ears adapt to the volume
level, so a volume level that does not cause discomfort might still damage your hearing.
Connecting the Clone Cable
You can transfer the programmed data to and from another BC796D scanner using a
RS232C Cable (9 pin to 9 pin) (not supplied). Connect the cable between each scanner’s
REMOTE jacks. See "Clone Mode" on page 73. You can also upload or download the
programmed data to or from a PC using an optional PC interface kit available through your
local electronics store.
Connecting the Tape Recorder
You can use a standard tape recorder or a VOX (Voice Operated Control) recorder. To
connect the recorder to the scanner, connect a cable with a 1/8 inch (3.5 mm) plug from the
tape recorder’s remote jack to the TAPE OUT jack on the back of the scanner. (Your local
electronics store should carry a wide selection of cables and tape recorders.)
Remember!
• You must mark a channel, ID, talkgroup, or bank for Recording in order for this feature to
work.
• This feature does not work if your scanner is set with MUTE ON.
To set the record for the channel.
2:SCAN OPTION→ 1:CONVENTIONAL→ select the channel number, then press E.
→ 8:RECORD→ 1:ON
To set the record for the search.
1:SERVICE OPTION→ :CHAIN SEARCH→ 6:RECORD→ 1:ON
To set the record for talkgroup ID.
2:SCAN OPTION→ 2:TRUNK→ select the bank, then press E → 3:TALK GROUP
→ select ID LIST, then press E → 3:RECORD→ 1:ON
To set the record for ID Searching (see “Searching for Active Talkgroups”),
2:SCAN OPTION→ 2:TRUNK-> select the bank, then press E → 5:RECORD→
1:ON
18
Basic Operation
This section is your main reference for using the scanner once you have programmed
conventional and trunked systems. Note that there are some slight differences to some
functions depending on whether you are trying to affect conventional operation or trunked
operation. Be sure to refer to the appropriate section depending on the mode you are using.
Turning On the Scanner
Turn the VOLUME control clockwise out of the detent position. The scanner automatically
starts scanning. Since there are no frequencies programmed in your scanner initially, you
may not receive any signals. Once you set the squelch and program some frequencies, you
will begin hearing conversations regularly.
Setting the Squelch
To set the squelch, you must be in the hold mode, and you should not be receiving a signal
on your scanner.
1. Press ▲/HOLD until you do not hear a signal.
STRONG SIGNALS
2. Make sure that the VOLUME is set to a comfortable listening
MEDIUM SIGNALS
level.
WEAK SIGNALS
3. Think of the Squelch Control as a gate. Turn the SQUELCH
control fully counterclockwise. This raises the “Squelch Gate” so
high that only very strong signals can get through.
NOISE
4. Turn SQUELCH clockwise until you hear a hiss. This lowers the
STRONG SIGNALS
“Squelch Gate” so that everything gets through – noise, weak
signals, medium signals and strong signals.
MEDIUM SIGNALS
WEAK SIGNALS
NOISE
5. Turn SQUELCH back counter-clockwise just until the hiss stops.
STRONG SIGNALS
Now the “Squelch Gate” allows only clear signals through.
MEDIUM SIGNALS
Note: For Trunk Scanning, a good squelch setting is critical. The
WEAK SIGNALS
recommended setting is midpoint. If you set the squelch too
high, the scanner might not reliably stop on the control
NOISE
channel.
19
Using the Menu
Many of your scanner’s functions are accessed through its menu system. For complete
information about a menu option, see the section referencing its use. A complete list of the
menu structure is included in the back of this manual. To select a menu item, first press
MENU to go to the first-level menu. Then, either press the number key corresponding to the
option you want to select, or use the scroll bar to highlight the option then press E.
To back up a menu level, press MENU.
Notes: • To change a setting that affects either a specific bank or channel, first select a
channel within the bank or the channel that you want to modify.
• To check the settings for a channel, press and hold MENU for 2 seconds.
In this manual, we represent navigation through the menu with the following nota-
tion:
MAIN MENU→ SUB MENU 1→ SUB MENU 2
For example to access the DIMMER LIGHT option, the notation is:
3:SYSTEM OPTION → 1:DIMMER
To access this option, press MENU, then scroll to each menu option and press E.
Or, press MENU, 3, 1.
• Some menu items are not numbered. To access these options, you must manual-
ly navigate to the selection using the scroll bar.
Manually Selecting a Channel
To manually select a channel, press ▲/HOLD, the channel number, then ▲/HOLD again.
The scanner displays the information stored in that channel.
Notes: • If the channel contains trunked system information, frequency data is not dis-
played.
• If you are trunk scanning, you need to first press TRUNK to exit the trunking
mode.
Scanning Programmed Channels
Before you can scan, you must first program channels. See the appropriate programming
section for complete instructions.
To begin scanning, simply turn on your scanner or, if the scanner is not currently scanning,
press SCAN. The scanner checks each system you have programmed that is not locked out
and stops if there is activity. SCANscrolls across the display, right to left.
When the scanner receives a signal on a programmed channel, it stops on that channel and
displays the channel information (text tag, channel number, trunk mode).
Locking/Unlocking Banks
When you are scanning conventional banks, the scanner displays the digit corresponding to
all unlocked banks. To lock out a bank so that the scanner does not scan its channels, press
the number that corresponds to the bank. The scanner replaces that bank’s number with a
dash.
20
To unlock locked-out banks, simply press that bank’s number again. The scanner displays
that bank’s number and includes it when scanning.
Note: You cannot lockout all banks. One bank must be unlocked at all times.
Locking/Unlocking Channels
To lock out a channel so that the scanner does not stop on it while scanning, press L/O
when the scanner is stopped on that channel or manually select the channel and press L/O.
To unlock the channel, manually select it and press L/O again.
Note: You cannot lockout all channels in a bank. One channel must remain unlocked. If you
want to lock out an entire bank, see the previous section.
Restoring All Locked Out Channels
To simultaneously unlock all channels, press ▲/HOLD, then press and hold L/O for 2
seconds. The scanner beeps twice and unlocks all channels.
Priority Scanning
When Priority Scan is turned on, the scanner checks the conventional priority channels in
the unlocked banks every 2 seconds or the priority ID’s in trunked systems every 4 seconds
between transmissions. If a signal is present on a priority channel, the scanner switches to
monitor that transmission, even if it had been stopped on another channel. One channel or
talkgroup ID in each bank is designated as the priority.
To turn on Priority Scan, repeatedly press PRI until the scanner displays PRIORITY ON. To
turn Priority Scan off, repeatedly press PRI until the scanner displays PRIORITY OFF.
Note: If all priority channels in unlocked banks are locked out, the scanner displays ERROR
when you try to turn on the priority scan mode.
Priority Plus Scanning
To scan only the priority channels in the unlocked banks, while scanning repeatedly press
PRI until the scanner displays PRIORITY PLUS. To turn off Priority Plus, repeatedly press
PRI to select PRIORITY ON or PRIORITY OFF.
Note: Priority Plus only operates in the scan mode; not in the hold or search mode.
Listening to the Input Channel
Repeater-based systems, such as public safety conventional, trunked systems, and some
other business and amateur radio systems, use two sets of frequencies – input frequencies
and output frequencies (see “Understanding Scanning”). You normally listen to the output
frequency, as it can generally be received from a much farther range. Sometimes, though,
you might want to know if the mobile unit is nearby. To do this, check the input frequency by
pressing RVRS. If you hear the transmission, then the mobile unit is probably within 2 or 3
miles of your location.
21
Dimmer Light Setting
The Dimmer Light setting sets the brightness of the display backlight.
3:SYSTEM OPTION → 1:DIMMER
1:HIGH
Set the backlight to the brightest setting
2:MEDIUM
Set the backlight to be dimmer
3:OFF
Set the backlight off
Controlling How Much Information Appears
The scanner normally displays trunk, frequency, receiving mode, and a signal meter when it
is scanning. This option allows you to reduce how much information your scanner displays.
3:SYSTEM OPTION → 2:SCREEN MASK
1:ON
Display all information
2:OFF
Display reduced information
Turning the Key Beep On/Off
When Key Tone is turned on, the scanner beeps each time you press a key.
3:SYSTEM OPTION → 3:KEY BEEP
1:ON
Turn on the key beep
2:OFF
Turn off the key beep
Locking the ENTER key
To prevent accidentally changing channel settings, you can lock the ENTER key.
3:SYSTEM OPTION → 4:ENTER LOCK
1:ON
The ENTER key is disabled.
2:OFF
The ENTER key operates normally.
Note: The ENTER key operates normally when selecting menu options, even when you set
the option to ON.
22
Disabling the APCO25 Card
If you are not in an area where there is an APCO 25 digital system, you can save power by
disabling the APCO 25 (P-25) card.
3:SYSTEM OPTION → 0:P-25 CARD
1:ENABLE
The card is enabled
2:DISABLE
The card is disabled
Muting All Audio
To mute all audio, press and hold MUTE for 2 seconds. The scanner operates normally, but
no audio sounds from the scanner. To turn audio back on, press and hold MUTE for 2
seconds.
Setting Squelch Mode
You can set the scanner to either stop on any transmission during searching or scanning, or
only stop on transmissions that include a specific CTCSS or DCS subaudible tone (see
“Understanding Scanning” for information about subaudible tones).
3:SYSTEM OPTION → 8:SQ MODE
1:CSQ
Carrier Squelch mode; the scanner stops on any transmission regardless of whether
a subaudible tone is present.
2:TONE SQ
The scanner stops on transmissions that include a matching subaudible tone or
have no tone at all. When you select this option, you also need to set the
appropriate tone in either the channel memory or for the search range.
3:TONE SEARCH
When the scanner stops on a transmission, it will then scan the subaudible tones to
determine the correct setting. When the scanner has found the correct tone, it
flashes the tone on the display. If you store that frequency into a channel, the tone
is also stored.
Trunk Scanning Options
When you are scanning a trunked system, there are several trunking-only options available
to you. This section outlines these options.
Searching for Active Talkgroups (ID Search)
If you want to hear all activity on a system, use the ID Search mode. While scanning a
trunking system, press SRCH while scanning that system; or, press and hold TRUNK until
the scanner flashes READY TO ID SEARCH. The BC796D stops on every active
talkgroup, regardless of whether you have programmed it into your scanner.
Notes: • If you have not yet programmed any ID’s for the system, this is the only mode
available.
23
• In the ID search mode, the scanner displays the alpha tags associated with the
stored talkgroups or NEW for talkgroups you have not stored.
Scanning Only Stored Talkgroups (ID Scan)
To scan only those talkgroups you have stored into your scanner, press SCAN while
scanning that system; or, press and hold TRUNK until the scanner displays READY TO
ID SCAN. When one of the talkgroups you have stored becomes active, the scanner
switches to that transmission and displays the ID number and the alpha tag for that talk
group.
Note: You must store at least two talkgroup IDs in the system for ID scanning to work.
Monitoring Talkgroup ID’s
To see all of the ID’s that are active on the system, while monitoring a trunked system press
TRUNK. The scanner stops trunking the system and instead holds on the system’s control
channel. You hear the control data and the scanner displays every talkgroup ID as it
becomes active in the system. To resume trunktracking, press TRUNK again.
Selecting Talkgroup Lists to Scan
When the scanner is in the ID Scan mode, you can select which ID lists you want the
BC796D to scan. First, if you are scanning a Motorola or EDACS system, ensure that you
are in the Scan List mode. Press RVRS until the scanner displays “List” at the left side of
line 3 in the display when it has not stopped on a talkgroup or on the left side of line 4 if it
has stopped on a talkgroup. Then, press the number corresponding to the ID list you want to
turn on or off.
Holding on a Single Talkgroup
To hold on an active talkgroup when scanning or searching, press ▲/HOLD. The BC796D
stops scanning and holds on the current trunking system. It only receives transmissions on
the talkgroup that was active when you pressed ▲/HOLD
To select a talkgroup to hold on when that talkgroup is not active, you must first program
that talkgroup into an ID list. Then, while scanning that system, use the scroll bar to select
the talkgroup ID to hold on.
To select a talkgroup to hold on when that group is not active, while ID scanning or ID
searching the system, press ▲/HOLD. Then, either enter the ID or (if you have stored the
ID) scroll to the ID you want to hold on.
Locking Out Talkgroups
Like conventional scanning, you can lockout unwanted talkgroup traffic on trunking systems.
This is particularly important if you are ID Searching a trunking system, as many systems
share both voice traffic (that you usually want to hear) with some data traffic from water
meter systems, door alarms, traffic signals and other data sources that you don’t want to
hear.
To lockout a talkgroup, press L/O when the scanner stops on that group. Or, if you have
stored the talkgroup in an ID list, select that ID and press L/O.
To unlock a talkgroup stored in a scan list, use the scroll bar to manually select that ID, then
press L/O to unlock it.
24
To unlock an ID you locked out during ID search or ID scan:
2:SCAN OPTION → 2:TRUNK → Select the Bank → 7:L/O ID REVIEW
Then, use the scroll bar to select the ID you want to unlock and press L/O.
Or, press ▲/HOLD then press L/O for 2 seconds to clear all the lockouts from the system.
EDACS Blockout
This is a powerful form of lockout that is only available for EDACS systems. EDACS
Blockout lets you lockout entire Agencies or Fleets, not just individual talkgroups. To use
blockout, while scanning an EDACS system, press ▲/HOLD then press L/O for 2 seconds to
clear all the lockouts from the system. Then enter the agency or the agency and fleet and
.
.
press
then L/O. For example, to lockout agency 4, press 04
L/O.
Unlocking All Talkgroups
To unlock all talkgroups for a system:
2:SCAN OPTION → 2:TRUNK → Select the Bank → 7:L/O ID REVIEW
Then, use the scroll bar to select the ID you want to unlock and press L/O.
Or, press ▲/HOLD then press L/O for 2 seconds to clear all the lockouts from the system.
EDACS Patch Tracking
EDACS systems sometimes bring several talkgroups together in a ‘Patch’. A patch might be
used by a police agency at night to provide a single channel with a single dispatcher for a
wide area. A patch is created when a single, temporary talkgroup substitutes for the original
talkgroups. While the patch is running, which may be for hours or days, the original
talkgroups cease to be used. If you were monitoring one of these talkgroups, you might think
there was no traffic, but in fact the talkgroup was operating at the different temporary
number.
If a talkgroup in your Scan List is patched, your scanner will continue to receive it under its
new identity until the patch has ended. When a patch is being received, the radio will display
PATCH ID, and will show the temporary common talkgroup plus all the included
talkgroups in a cycling display. The BC796D is limited to following one patches. The
temporary talkgroups used for patches are usually found in AFS code 15-xxx, and
sometimes 00-xxx.
25
Searching
Your BC796D includes powerful search features that let you discover new active frequencies
in your area. You can save up to 10 custom search ranges in your scanner. This section
details how to use custom search ranges and also details the various settings that affect
search operation.
To start a search, first program one or more search ranges (see “Setting a Search Range”).
Then, press SRCH. The scanner begins searching within the selected search range. To
change to a different search range, press the number button associated with that range.
By default, your scanner only searches one range at a time. To search multiple ranges, turn
on Chain Search (see “Setting Chain Search”). When you turn on Chain Search, each time
you press a number button, the associated range is turned on or off. Note that you must
have at least one range turned on at all times.
Holding on an Active Frequency
To hold on the current frequency, press ▲/HOLD. To resume searching, press RSM.
Setting Chain Search
1:SERVICE OPTION → :CHAIN SEARCH → 1:CHAIN SEARCH
1:ON
The scanner allows you to search multiple ranges simultaneously.
2:OFF
The scanner searches only one range at a time.
Setting Data Skip
The scanner normally stops on any frequency with activity, and remains there until either the
activity stops or you press RSM or use the scroll bar to resume scanning. However, some
signals are identifiable by the scanner as data signals, and you can set the scanner to
automatically skip these channels.
3:SYSTEM OPTION → 7:DATA SKIP
1:ON
The scanner skips data frequencies.
2:OFF
Data skip is turned off.
Note: Even with this option turned on, the scanner might pause for a couple of seconds on
data transmissions before resuming.
Skipping Frequencies
If a particular frequency continues to interrupt search scanning, it is possible to set your
scanner to skip the frequency.
26
To skip over a frequency, press L/O when the scanner is stopped on a frequency you want
to skip.
Notes: • You can program up to 200 skip frequencies. The 201st skip frequency entered
causes the first skipped frequency to unlock.
• If all frequencies in the search range are set to skip, a beep sounds and it moves
to Search Hold mode. To resume searching:
1) Unskip all skipped frequencies
—- OR —-
2) Select a different Search Frequency range.
To unskip all skipped frequencies, press and hold L/O for 2 seconds in Search
Hold mode.
Storing Found Frequencies
If you find a frequency you want to save into a channel, simply press TRNFR when the
scanner is stopped on that frequency. The scanner displays the lowest-numbered empty
channel. Use the scroll bar to select the channel you want to save the frequency into, then
press E.
Notes: • If you have already stored this frequency, the scanner displays WARNING
DUPLICATE and the channel where the frequency is stored. To store the frequen-
cy anyway, press E again.
• After you store the frequency, the scanner resumes searching.
• If all channels are used, the scanner defaults to the last-used channel prior to enter-
ing the search mode.
Automatically Storing Frequencies
During searching, you can have the scanner automatically store active frequencies into a
bank you choose.
1:SERVICE OPTION → :CHAIN SEARCH → 7:AUTO STORE
1:ON
→
1. Press the numbers corresponding to the banks you want the scanner to store found
frequencies into.
2. Press SRCH to start the auto-store operation.
3. Press ▲/HOLD to stop auto-store. The scanner exits the auto-store mode.
Note: To ensure that you catch most active frequencies for the band, you should allow the
auto-store operation to continue through at least a few complete sweeps of the band.
Depending on the types of services, some occasionally active frequencies might not
have activity for minutes or hours at a time.
27
Setting Subaudible Tones for Searching
You can set the scanner to only stop on transmissions that either have no subaudible tone
or include a specified CTCSS or DCS tone during searches. This setting affects all search
ranges. For this feature to work, you need to turn on the Tone Mode (see “Setting Squelch
Mode”).
1:SERVICE OPTION → :CHAIN SEARCH → 5:TONE DATA
1:CTCSS
Lets you set the CTCSS tone.
2:DCS
Lets you set the DCS.
3:OFF
Does not use subaudible tones.
Note: If, instead of pressing E to select a tone you press L/O, the scanner will stop on any
transmission except for those with the selected tone.
Searching for Subaudible Tones
If you set the system tone option to 3:TONE SEARCH(see “Setting Squelch Mode”), the
scanner will determine the correct tone for the received signal.
Attenuating All Search Ranges
If you are near a strong RF source, you might need to attenuate the input signal in order to
search properly. To turn on this option for all search ranges:
1:SERVICE OPTION → :CHAIN SEARCH → 4:ATTENUATOR
1:ON
The attenuator is turned on.
2:OFF
The attenuator is turned off.
Setting DELAY for All Search Ranges
You can set the scanner to have a delay after the end of a transmission before searching
resumes. This slows searching, but helps you prevent missing replies on a frequency.
1:SERVICE OPTION → :CHAIN SEARCH → 3:DELAY
1:NONE
The delay is turned off.
2:1 SECOND
The delay time is 1 second.
3:2 SECONDS
The delay time is 2 seconds.
4:4 SECONDS
The delay time is 4 seconds.
28
5:INFINITE
When the scanner stops on a transmission, you must press RSM to resume
searching.
6: -2 SECONDS
The scanner only stops on transmissions for 2 seconds, then automatically
resumes. To hold on the transmission, press ▲/HOLD during the 2-second pause.
7: -5 SECONDS
The scanner only stops on transmissions for 5 seconds, then automatically
resumes. To hold on the transmission, press ▲/HOLD during the 5-second pause.
8: -10 SECONDS
The scanner only stops on transmissions for 10 seconds, then automatically
resumes. To hold on the transmission, press ▲/HOLD during the 10-second pause.
Setting a Search Range
Before you can use a range search, follow these steps to program at least one of the 10
custom search ranges.
1. Activate the search range mode by using the menu:
1:SERVICE OPTION → :CHAIN SEARCH → 2:SEARCH RANGE
or by pressing and holding SRCH for 2 seconds.
2. Use the scroll bar to select the range you want to program, then press E.
3. Set the following options:
1:RANGE
Select, then follow the prompts to enter the lower and upper frequency limits for the
search range.
2:STEPS
Select, then set the step size to use while searching the custom range. If you select
9:AUTO, the scanner will use the step sizes most often assigned for each band.
3:MODE
Select, then set the modulation mode to use while searching the custom range. If
you select 5:AUTO, the scanner will use the modulation mode most often used for
each band.
4:ALPHA TAG
Select, then assign an alpha tag to the search range.
5:TRUNK
See “Searching for Trunk Systems.”
4. Press MENU, then repeat Steps 2 and 3 for additional search ranges.
Searching for Trunk Systems
1:SERVICE OPTION → :CHAIN SEARCH → 2:SEARCH RANGE
Select the range → 5:TRUNK
→
This option lets you search for a Motorola trunking control channel within the selected range.
To activate this function, select 1:ON, then select an appropriate trunk plan. Most areas use
29
Plan 1, so this setting should work in most cases.
Note: This feature only works for 800 MHz and 900 MHz Motorola trunking systems.
If the scanner detects a trunking control channel, it will begin to track that system. The
scanner displays the talk group numbers as they become active.
30
Service Search
The Service Search feature lets you scroll through the following twelve preprogrammed
services. The frequencies selected for these services are the most commonly used around
the U.S.
• 1:WEATHER
• 7:RAILROAD
• 8:AIR
• 2:PUBLIC SAFETY
• 3:NEWS
• 9:CB RADIO
• 0:FRS & GMRS
• :RACING
• 4:TV BROADCAST
• 5:HAM RADIO
• 6:MARINE
• :SPECIAL
Note: Special Frequencies are low-power, itinerant, “splinters” and other frequencies which
are commonly used at special events and other locations and may or may not be
licensed.
To access this feature:
1. Press SRVC.
––– OR –––
Use the menu to select 1:SERVICE OPTION.
2. Select a preprogrammed service to search by selecting from the Service Search menu.
Note: Except for Weather, when you press E to select a service, searching begins
immediately. For weather search options, see “Using Weather Search and
Weather Alert.”
Service Search Skip
You can set the scanner to skip up to 100 unwanted frequencies during Service Search.
To skip over a frequency, press L/O when the scanner has stopped at a frequency you
want to skip.
To restore a skipped frequency during search, press ▲/HOLD select the desired
frequency using the scroll bar, then press L/O.
To restore all skipped frequencies, press and hold L/O for 2 seconds.
Notes: • You can not skip frequencies in the Weather Service mode.
• If you start Service Searching for a service that has all frequencies locked out,
you hear a beep and the scanner moves to the Hold mode.
31
Using Weather Search and Weather Alert (SAME)
Your scanner allows you to either search for a local NOAA weather broadcast, or be set to
alert when a SAME weather alert is broadcast on a NOAA channel.
Searching for a Weather Broadcast
To search for a weather broadcast in your area:
1:SERVICE OPTION → 1:WEATHER → 1:MONITOR
The scanner begins to search the frequencies used by the National Weather Service for
these broadcasts. When it finds a broadcast, it stops on the channel until you select another
option or reception of the signal stops.
Note: NOAA broadcasts are continuous broadcasts. You will only lose reception if you
move out of a coverage area. If the signal is lost, the scanner resumes searching for
a weather transmission.
Using Weather Alert (SAME)
Important: Your scanner has been primarily designed to be a radio scanner. While it
incorporates weather alert as one feature, we strongly recommend that you not use the
scanner as your sole means for receiving emergency alerts. Your local electronics retailer
carries several weather radios specifically designed for this function.
SAME (Specific Area Message Encoding) was adopted late in the last century to replace the
wide-area alerts previously used. Weather alerts today are preceded by a digital packet that
identifies not only the type of alert, but also the geographic location for the alert. Thus, it is
possible for a weather broadcast that can be received across many counties to be targeted
to a single county.
To specify a county, SAME uses a standard established by the US Census bureau, called
FIPS. The format of a FIPS code is:
DSSCCC
Where
D = area subdivision (0=entire area)
SS = State code (00=all states)
CCC = County code (000=all counties)
For example, the FIPS code for Tarrant County, Texas is:
048439 (48=Texas; 439=Tarrant County).
Some counties are further subdivided, in which cases, the first digit will be 0 for all
subdivisions in the county and each subdivision will be labeled 1-9.
To program your scanner to alert you when the weather service issues an alert, you must
set the scanner to the alert mode, and then leave the scanner monitoring the weather
service. You cannot scan and monitor for weather alerts at the same time.
32
To limit alerts to a specific area, you must also program in the FIPS code(s) for the area(s)
you want to receive alerts for. The scanner can be set to either alert for all areas, or only the
areas you have programmed. You can get FIPS codes for your area by calling the National
Weather Service at 1-888-NWR-SAME or visit their web site at
To program weather alert operation:
1:SERVICE OPTION → 1:WEATHER → 2:ALERT
1. Select 1:ONto turn on weather alert.
2. Use the scroll bar to select either ALL FIPS or one of the 15 programmable FIPS
positions.
3. If you need to program a FIPS code, press E, then enter the code and press E again.
4. Press MENU two times.
5. Select 1:MONITOR.
The scanner displays WX ALERT ON. All audio is muted until an alert is received.
Note: If you lose power or turn off the scanner, the scanner keeps the weather alert mode.
Warning: Never listen to the scanner using a headphone or earphone when you have put
the scanner in the weather alert mode. The volume control is disabled in this
mode, and the loud alert sound could damage your hearing.
If an event is issued, the scanner displays the text for the event and sounds an alert. The
alert sound used depends on the type of event received:
Statements: 2-tone beep
Watches:
2-tone trill
Warnings: Siren
The chart in the back of this manual details the various events and the type of alert
produced.
Testing the Weather Alert
To test the alert to see what each alert sounds like, monitor the weather mode, then press
▲/HOLD. Hold PRI for 2 seconds to start the test. Press any key to exit the test. The
scanner sounds each of the three alert types repeatedly.
Warning: Never listen to the scanner using a headphone or earphone when you are testing
weather alert. The volume control is disabled in this mode, and the loud alert
sound could damage your hearing.
33
Programming Bank Information
In addition to channel and trunking system information you program into each bank (covered
in the following sections), this section covers general bank information.
Bank Configuration
Each of your scanner’s banks holds 100 channels that can be a mix of conventional (non-
trunked) channels and one trunking system. Bank 1 holds Channels 001-100, Bank 2 holds
Channels 101-200, and so on through Bank 0 which holds Channels 901-1000.
Additionally, each bank that includes a trunking system can also hold up to 100 Talkgroup
ID’s for that system.
Assigning Bank Names
To give a bank a name that the scanner displays when it stops on a channel in that bank:
3:SYSTEM OPTION → 9:BANK TAG
1. Use the scroll bar to select the bank you want to tag, then press E.
2. Use the scroll bar to select the letter, then press ▲/HOLD to move the entry position one
space to the right or press LIMIT/▼ to move the entry position one space to the left.
3. When you have entered the tag, press E to save the tag and return to Step 1.
34
General Programming
This section includes procedures that apply regardless of whether you are programming
conventional or trunked channels.
Deleting Frequencies from Channels
To delete a stored frequency, manually select the channel, then press 0 and E. The contents
of the channel are erased.
Transferring Channel Information
To transfer settings from one channel to another:
1. Manually select the channel with the information you want to transfer.
2. Press TRNFR. The scanner displays the lowest-numbered empty channel. To select a
different channel, use the scroll bar to select the channel.
3. Press E. All channel information is stored in the target channel and deleted from the
original channel.
Note: Trunking system information is not transferred.
Entering Alpha Information
Your BC796D lets you assign text tags to banks, channels, talkgroups, and search ranges.
Follow these steps to enter a text tag.
1. Use the scroll bar to select the letter.
2. Press ▲/HOLD to advance to the next letter or LIMIT/▼ to back up to a previous letter.
3. When you have completed the text tag, press E to accept the entry.
General Programming Tips
• Do not program weather frequencies into channels. Since they have continuous broad-
casts, your scanner will always stop on them. Use weather service search to access
NOAA weather broadcasts.
• Group related services into a bank. For example, program city trunk system in Bank 1,
amateur radio in Bank 2, and so on.
• To quickly program a series of channels, start with the lowest-numbered channel. The
scanner automatically advances to the next channel by default when you complete pro-
gramming a channel.
• Make a programming plan before you sit down to program your scanner. Write down what
frequency you will store in each channel, along with other system information. Or, use the
supplied software to organize your information before you start. Keep a record of what you
programmed in case you lose programming. This lets you more quickly program the scan-
ner the next time.
35
• Entered frequencies are rounded off according to the step size for the channel.
• When you store a new frequency in a channel, the text tag previously assigned to that
channel is deleted.
36
Programming Conventional Channels
Each bank can hold a mix of conventional channels plus one trunking system. This section
describes how to store known frequencies into conventional channels. The first few sections
are intended to be performed in the order indicated if you are entering information the first
time. If you are editing existing information, manually select the channel, then use the
complete menu process to access the information you want to change.
Note: To quickly store only a frequency in a channel, manually select the channel, enter the
frequency, then press E. Do not use this method for Trunking systems, however, as
these systems require additional information to scan correctly.
1. Select a Channel to Program
To start, first select the channel you want to program:
2:SCAN OPTION → 1:CONVENTIONAL
Enter the channel number, then press E.
2. Enter the Frequency
a. Press 1 or highlight 1:FREQUENCYand press E.
b. Enter the frequency you want to program, then press E.
Notes: • If the channel already had a frequency programmed, it appears above the prompt.
• If you select a frequency that is not valid, the scanner displays ERROR OUT
OF BAND. Enter a correct frequency to continue.
• If you enter a frequency that has already been stored in the scanner, the scanner
displays WARNING DUPLICATEand the channel number that contains the
.
duplicate. To save the frequency anyway, press E. Otherwise, press
to cancel
and enter a different frequency.
• If you change an existing frequency, all other information stored for that channel
is deleted or set back to default values.
3. Assigning a Text Tag
a. Use the scroll bar to select the channel you want to tag, then press E.
b. Use the scroll bar to select the letter, then press ▲/HOLD to move the entry position one
space to the right or press LIMIT/▼ to move the entry position one space to the left.
c. When you have entered the tag, press E to save the tag.
The scanner displays
1:OTHER CHANNEL
Select to pick another channel to program from Step 1
2:CHANNEL OPTION
Select to set additional channel options (see the following sections).
37
3:DONE
Exit the channel setting and menu mode.
Setting the Delay
2:SCAN OPTION → 1:CONVENTIONAL → Channel No. → 2:DELAY
The delay option lets you set a delay after a transmission for each channel. This slows down
scanning, but helps to prevent missing replies.
1:NONE
The delay is turned off.
2:1 SECOND
The delay time is 1 second.
3:2 SECONDS
The delay time is 2 seconds.
4:4 SECONDS
The delay time is 4 seconds.
5:INFINITE
When the scanner stops on a transmission, you must press RSM to resume
searching.
6: -2 SECONDS
The scanner only stops on transmissions for 2 seconds, then automatically
resumes. To hold on the transmission, press ▲/HOLD during the 2-second pause.
7: -5 SECONDS
The scanner only stops on transmissions for 5 seconds, then automatically
resumes. To hold on the transmission, press ▲/HOLD during the 5-second pause.
8: -10 SECONDS
The scanner only stops on transmissions for 10 seconds, then automatically
resumes. To hold on the transmission, press ▲/HOLD during the 10-second pause.
Setting the Subaudible Tone Option
2:SCAN OPTION → 1:CONVENTIONAL → Channel No. → 3:TONE DATA
Some radio systems use special tones to prevent interference from other nearby systems
operating on the same frequencies. When tones are being used, the radios only open
squelch when a transmission with a matching tone is present on the frequency. Some
services, such as FRS, GMRS, and Business Band refer to these tones as Quiet Codes,
Privacy Codes, or similar and use a number to associate a particular tone. The table in the
back of the manual provides a cross reference to common associations. For this feature to
work, you need to turn on the Tone Mode (see “Setting Squelch Mode”).
1:CTCSS
Continuous Tone Coded Squelch System (CTCSS) is used with Amateur Radio,
FRS, GMRS, Business Band, and other systems. When you select this option, the
scanner only opens squelch when a matching CTCSS tone is present on the
frequency.
2:DCS
38
Digital Coded Squelch is similar to CTCSS, but instead of differentiating codes
using frequencies, DCS always uses the same frequency but encodes it with a
binary value. When you select this option, the scanner only opens squelch when a
matching DCS value is present on the frequency.
3:OFF
The scanner opens squelch regardless of the presence of tones.
Note: If, instead of pressing E to select a tone you press L/O, the scanner will stop on any
transmission except for those with the selected tone.
Setting Beep Alert
2:SCAN OPTION → 1:CONVENTIONAL → Channel No. → 4:BEEP
ALERT
1:ON
The scanner sounds three alert tones when it stops on a transmission on this
channel.
2:OFF
Beep Alert is off.
Setting the Attenuator
2:SCAN OPTION → 1:CONVENTIONAL → Channel No.
5:ATTENUATOR
→
If you are near a very strong signal source, the signal can overload the scanner’s RF front
end, causing poor audio quality or missed reception.
1:ON
RF attenuation is on for the channel
2:OFF
RF attenuation is off for the channel
Changing the Frequency Step
2:SCAN OPTION → 1:CONVENTIONAL → Channel No. → 6:STEPS
The channel frequency step option controls the frequency step size used when you manually
tune up or down from the frequency stored in the channel. Your BC796D is preprogrammed
with the most common steps sizes for each band, so you seldom need to change this
setting.
1:5KHz
Use 5 kHz steps
2:6.25KHz
Use 6.25 kHz steps
3:7.5KHz
Use 7.5 kHz steps
4:10KHz
Use 10 kHz steps
5:12.5KHz
Use 12.5 kHz steps
39
6:25KHz
Use 25 kHz steps
7:50KHz
Use 50 kHz steps
8:100KHz
Use 100 kHz steps
9:AUTO
Automatically set the step size based on the band
Setting the Modulation Mode
2:SCAN OPTION → 1:CONVENTIONAL → Channel No. → 7:MODE
Radio transmissions are modulated in several different ways. The BC796D is able to
demodulate the most common transmission types. Your scanner has the most common
modulation mode preset for each band, so you seldom have to change this option. However
there are occasional services that use a modulation mode that is not standard for that band.
1:AM
Amplitude Modulation
2:FM
Frequency Modulation
3:WFM
Wideband FM
4:NFM
Narrowband FM
Setting Priority Channels
You can set one conventional channel in each bank as a priority channel. When you turn on
the Priority Scan option (see “Priority Scanning”), the scanner automatically checks these
channels every 2 seconds to see if there is activity. If there is, the scanner immediately
switches to the priority channel.
Notes: • The scanner does not check priority channels in locked-out banks.
• The scanner does not check priority channels if the channel is locked out.
By default, the first channel of each bank is set as priority. To change the priority channel:
1. Manually select the channel you want to set as priority.
2. Press and hold PRI for 2 seconds. The scanner beeps and the new priority assignment
is made.
Note: To program priority talkgroup ID’s for trunk scanning, see “Setting Priority
Talkgroups.”
40
Programming Trunked Systems
Your BC796D is designed to scan most major types of trunking systems, including APCO
Project 25 Phase 1 digital communication systems. These systems are briefly described
here. For a more technical description of each system, see “Understanding Scanning.”
General trunking options are also covered in this section. To program the systems, refer to
the sections in the manual referenced below
• APCO Project 25 Phase 1 Systems — Digital systems that support the APCO Project 25
protocol developed by the Association of Public Safety Communications Officials (APCO),
the Telecommunications Industry Association (TIA) and Electronic Industries Alliance
(EIA). Systems can operate in conventional, trunked (9600), trunked (3600) and mixed-
modes (analog and digital) in any frequency band including UHF, VHF, 800 MHz, and 900
MHz. See “Programming Motorola Systems.”
• MOTOROLA – Including Type I, Type II, Hybrid, SMARTNET, and Privacy Plus. Motorola
systems are widely used by public safety and business users. Most are on the 800 MHz
band, and recent systems are appearing on other bands. See “Programming Motorola
Systems.”.
• EDACS – Including “Wideband” 9600 baud, and “Narrowband” 4800 baud systems.
“Wideband” systems are mostly on the 800 MHz band, and are used by public safety, utili-
ties, and business users. Some systems are used on the VHF and UHF bands.
“Narrowband” systems are used in the 935-940 MHz band, many by utilities. See
“Programming EDACS Systems.”
• EDACS SCAT – These systems are mainly used in the Midwestern United States and are
one-channel trunking sites using the EDACS format. See “Programming EDACS
Systems.”
• LTR – These systems are mostly for business users, and found on the UHF, 800 and 900
MHz bands. See “Programming LTR Systems.”
When tracking these types of systems, remember these important points:
• Your scanner defaults to monitor Motorola Type II systems; however, you can change this
if the system in your area is different.
• The frequencies for many of the trunked public safety systems are listed in the
TrunkTracker National Public Safety Trunked System Frequency Guide included with your
BC796D scanner. Frequencies sometimes change, check with scanner.uniden.com for the
latest information.
41
Setting Trunking Delay
Setting a delay for trunking systems helps to ensure that you do not miss replies while
scanning.
2:SCAN OPTION → 2:TRUNK → Select the bank → 4:DELAY
1:NONE
The delay is turned off.
2:1 SECOND
The delay time is 1 second.
3:2 SECONDS
The delay time is 2 seconds.
4:4 SECONDS
The delay time is 4 seconds.
5:INFINITE
When the scanner stops on a transmission, you must press RSM to resume
searching.
6: -2 SECONDS
The scanner only stops on transmissions for 2 seconds, then automatically
resumes. To hold on the transmission, press ▲/HOLD during the 2-second pause.
7: -5 SECONDS
The scanner only stops on transmissions for 5 seconds, then automatically
resumes. To hold on the transmission, press ▲/HOLD during the 5-second pause.
8: -10 SECONDS
The scanner only stops on transmissions for 10 seconds, then automatically
resumes. To hold on the transmission, press ▲/HOLD during the 10-second pause.
Using I-Call (Motorola and EDACS only)
I-Calls are direct unit-to-unit transmissions that are not heard by other users. Your BC796D
can monitor these transmissions in either the search mode or (if you have stored the unit
number as a talkgroup) in the scan mode.
When the scanner stops on an I-Call, the scanner displays the individual radio unit ID
instead of a talkgroup ID.
EDACS or Motorola Type 1
Motorola Type 2
i nnnnn
7 nnnnn
Note: • Each radio in a system has its own unique unit ID. Unit ID’s are not published for
systems, and since officers might not use the same radio every day, it is difficult
to predict who and what you will hear for a specific radio ID.
• Since a conversation consists of two or more radios, and each radio has its own
ID, if you hold on an I-Call, you will only hear one side of the conversation.
Turning I-Call On and Off for ID Search
2:SCAN OPTION → 2:TRUNK → Select the bank → 9:I-CALL
1:ON
42
The scanner will stop on I-Calls or normal talkgroups.
2:OFF
The scanner ignores I-Calls.
3:ONLY
The scanner only stops on I-Calls.
Turning I-Call On for ID Scan
.
To receive I-Calls for ID Scan, simply store the radio unit number as ( ) plus the unit
number in place of the talkgroup. To receive any I-Call while scanning, enter the I-Call
.
wildcard ( ) 0. For EDACS and Motorola Type 1 systems, this appears as i0; for Motorola
Type 2 systems, this appears as 700000.
Setting Priority Talkgroups (Motorola and EDACS only)
Talkgroup priority works slightly different than conventional priority. With talkgroup priority,
the priority talkgroups are only checked when the scanner is on the control channel. So, if
you have delay turned on for the system or are holding on an ID, the scanner will
immediately switch to the priority talkgroup if it becomes active during the delay or while
there is no transmission on the held talkgroup.
To assign a talkgroup as the priority talkgroup, select it in Scan Hold mode (see “Holding on
a Single Talkgroup”). Then, press and hold PRI for 2 seconds.
Multi-Track
The BC796D allows you to track more than one system at a time. Here are some highlights
of this feature:
❖
❖
❖
You can actually track up to 10 trunking systems at one time.
You can trunk, scan, or search and scan conventional frequencies at the same time.
You can program conventional frequencies in the same bank as trunking systems.
After the scanner finishes checking a trunked system for activity, it will conventionally
scan the other frequencies in the bank (remember, only trunking frequencies are
programmed in Trunk mode).
To scan a mix of trunking and conventional banks, select the banks you wish to be active,
and then press SCAN. The scanner will instantly begin scanning. If you have not
programmed a trunking bank with talkgroup ID’s, you will receive NO ID (----)
message for that bank.
You can switch to Search mode and the scanner will search for any active ID’s on the
system.
Note: To switch ID Scan or ID Search, press and hold TRUNK or, press SCAN or SRCH
while scanning.
Multi-Track Operational Details
When more than one trunk system is active (for example two or more trunked systems or a
trunked system and one or more conventional frequencies), the radio jumps between
systems/frequencies as follows:
43
TRUNK SCAN: The scanner moves to a trunked system and looks for IDs in your Scan
List(s) for up to 1 second. If it finds no activity on your programmed talkgroups, it moves
on to conventional channels in the same bank or to the next active bank.
If the scanner finds that a talkgroup in one of your active Scan Lists becomes active, you
will begin to hear that communication and the scanner will display the proper talkgroup
number and any alpha tag. When the communication ends, the scanner will wait for 2
seconds for any further replies and, if none, the scanner will move to the conventional
channels in the same bank or to the next bank. The scanner will not look for any other
IDs within the same trunked system (as this would slow the scan process). If you press
RSM while you are listening to one ID, the scanner will check to see if another ID in your
Scan List is active. It will disregard the ID to which you were just monitoring.
TRUNK SEARCH: This mode works similarly to Trunk Scan. If the scanner finds any (non-
locked-out) ID when it checks the control channel, you will hear it. You will then hear any
replies that follow within 2 seconds. After that the scanner will move on and not
continuously search the system for additional IDs (on busy systems you would never leave
the system if this were the case). If you press the RSM key while monitoring one ID, the
radio will check if any other IDs are active (it will disregard the ID you just left), and if none
are active, it will move on.
44
Programming Motorola Systems
Follow the instructions in this section to program information for Motorola Type I, II, IIi
Hybrid, and APCO 25 Digital trunking systems.
Using Control Channel Programming
Your scanner has a powerful feature that lets you program in only the control channels for
Motorola 800 and 900 MHz systems. This can greatly shorten the time it takes to program
system information.
2:SCAN OPTION → 2:TRUNK → Select the bank → :CNTRL CH ONLY
For 900 MHz systems, you can then simply turn the feature on or off. For 800 MHz systems,
you need to select the band plan for the system:
1:PLAN1
Use if the last three digits of all of the frequencies used by the system end in 125,
375, 625, or 875.
2:PLAN2
Use if the highest frequency used by the system is above 866 MHz and if the last
three digits end in 000, 125, 250, 375, 500, 625, 750, or 875.
3:PLAN3
Use if the last three digits of all the frequencies in the system end in 000, 250, 500,
or 750.
4:PLAN4
Use if the highest frequency in the system is below 866 MHz and if the last three
digits end in 000, 125, 250, 375, 500, 625, 750, or 875.
5:OFF
Select to turn off control channel programming for this bank.
Note: • Many systems alternate control channels. To properly track the system, you need
to program all alternate control channels.
• If you do not know all of the frequencies for a system, but know at least one con-
trol channel, start by selecting Plan 1 (the most common type). If you notice that
you seem to be missing transmissions and replies, try each of the other plans
until you find the one that works best.
Programming Type 2/Digital 800 and 900 MHz Systems
To program a Type 2/Digital 800 or 900 MHz system, you need to know the frequencies that
the system uses.
1. Select the trunk programming mode.
2:SCAN OPTION → 2:TRUNK
2. Use the scroll bar to select the bank you want to program, then press E.
1:TRUNK TYPE → 1:ON
45
3. Select one of the following trunk types for Motorola Type 2 or digital Systems:
1:TYPE2/P25 800
Motorola Type 2 or Digital systems in the 800 MHz band
3:TYPE2/P25 900
Motorola Type 2 or Digital systems in the 900 MHz band
4. Select the channel to store the information into.
2:TRUNK CHANNEL
Use the scroll bar to select a channel within the bank to store a system frequency, then
press E.
5. Store the channel information
1:FREQUENCY
Enter the frequency for the channel, then enter an Alpha Tag for the channel.
Repeat Steps 4 and 5 to store the rest of the frequencies for the system. Then, see
“Programming Talkgroups.”
Programming Type2/Digital VHF and UHF Systems
To program a Type 2/Digital VHF or UHF system, you need to know the frequencies the
system uses and also the Base, Space, and Offset settings. These settings are normally
provided along with the system frequencies.
1. Select the trunk programming mode.
2:SCAN OPTION → 2:TRUNK
2. Use the scroll bar to select the bank you want to program, then press E.
1:TRUNK TYPE → 1:ON
3. Select one of the following trunk types for Motorola Type 2 or digital Systems:
4:TYPE2/P25 UHF
Motorola Type 2 or Digital systems in the UHF (450 – 512 MHz) band
5:TYPE2/P25 VHF
Motorola Type 2 or Digital systems in the VHF (148 – 406 MHz) band
4. Set the Base, Space and Offset settings.
Note: Your BC796D allows you to enter up to three Base, Space, Offset configurations.
However, most systems only use one configuration.
a. Use the scroll bar to select the configuration to program, then press E.
BASE CONFIG 1
b. Enter the system’s base frequency, then press E.
c. Enter the system’s space frequency, then press E.
d. Enter the system’s channel offset, then press E.
Repeat a-d or press MENU three times to continue programming the system.
46
5. Select the channel to store the information into.
2:TRUNK CHANNEL
Use the scroll bar to select a channel within the bank to store a system frequency, then
press E.
6. Store the channel information
1:FREQUENCY
Enter the frequency for the channel, then enter an Alpha Tag for the channel.
Repeat Steps 5 and 6 to store the rest of the frequencies for the system. Then, see
“Programming Talkgroups.”
Programming Type I and IIi Hybrid Systems
To program a Type I or IIi Hybrid system, you need to know the system’s fleet map in
addition to the frequency information for the system. Fleet map information is usually
provided with the frequencies for the system.
1. Select the trunk programming mode.
2:SCAN OPTION → 2:TRUNK
2. Use the scroll bar to select the bank you want to program, then press E.
1:TRUNK TYPE → 1:ON
3. Select the following trunk type for Motorola Type I Systems:
2:TYPE1
Motorola Type I and IIi Hybrid Systems
4. Enter the fleet map information.
Your scanner has the most common fleet maps preprogrammed. Refer to Appendix for a
complete list of these fleet maps.
Use the scroll bar to select the preprogrammed fleetmap 1-16 or, if the fleet map does
not match a preprogrammed set, select USER CUSTOM. Then, use the scroll bar to
select the size code for each block.
5. Select the channel to store the information into.
2:TRUNK CHANNEL
Use the scroll bar to select a channel within the bank to store a system frequency, then
press E.
6. Store the channel information
1:FREQUENCY
Enter the frequency for the channel, then enter an Alpha Tag for the channel.
Repeat Steps 5 and 6 to store the rest of the frequencies for the system. Then, see
“Programming Talkgroups.”
47
Toggling the Status Bit
Motorola talkgroup ID’s are sent as a 16-bit binary number. Normally, the last 4 positions in
the number are 0’s, which result in all talkgroups being equally divisible by 16. These last
four bits, however, can be used by the trunking system to indicate various status conditions.
For example, an emergency status could be indicated by setting the second-from last digit to
1. Talkgroup 33264, then would be sent on the system as 33266 when the radio triggered its
emergency status. By default, the BC796D ignores the last four digits of every talkgroup,
effectively rounding them down to the nearest multiple of 16 regardless of the status bits.
2:SCAN OPTION → 2:TRUNK → Select the bank → 0:STATUS BIT
1:ON
Talkgroups are rounded down to the next multiple of 16.
2:OFF
Talkgroups are not rounded down, so you can determine the value of the status
bits.
Toggling End Code Detect
At the end of each transmission, a digital burst is sent so that radios on the system will
quickly switch back to the control channel. Your scanner also listens for this code.
2:SCAN OPTION → 2:TRUNK → Select the bank → :END CODE
1:DETECT
The scanner detects the end code and immediately switches back to the control
channel.
2:IGNORE
The scanner waits for the carrier to drop before switching back to the control
channel.
48
Programming EDACS Systems
Follow the instructions in this section to program information for EDACS Wide, EDACS
Narrow, and EDACS SCAT trunking systems. Note that to program these systems, in
addition to knowing the system type and frequencies used, you must know the logical
channel numbers (LCN) for the system’s frequencies. This information is usually provided
with the frequency and other information. For more information refer to “Understanding
Scanning.”
Programming EDACS Channels
1. Select the trunk type.
2:SCAN OPTION → 2:TRUNK → Select the bank → 1:TRUNK TYPE
→ 1:ON
6:EDCS WIDE
Select for 9600 baud EDACS systems.
7:EDCS NARROW
Select for 4800 baud EDACS systems.
8:EDCS SCT.
Select for EDACS SCAT systems.
2. Program each trunk channel in LCN order (not frequency order). If you program this in
the wrong order, the scanner will not go to the correct channel when scanning.
2:TRUNK CHANNEL
ENTER CHANNEL No.
a. Enter the channel to program.
1:FREQUENCY
b. Enter the frequency then the alpha tag for the channel
Repeat a and b for each channel in the system.
Note: EDACS SCAT systems use only one channel.
Once you complete channel programming, see “Programming Talkgroups.”
Setting EDACS Emergency Alert
When the emergency status is sent on an EDACS radio, you can have your scanner alert
you to the transmission.
2:SCAN OPTION → 2:TRUNK → Select the bank → 0:EMERGENCY ALT
1:ON
The scanner beeps three times to alert you and flashes EMERGENCY during
emergency transmissions.
2:OFF
The scanner does not handle emergency transmissions any differently than other
transmissions.
49
Setting EDACS Decimal Mode
By default your scanner displays EDACS talkgroups in AFS format (see “Understanding
Scanning”). However, you can use this option to display and enter talkgroups in digital
format.
2:SCAN OPTION → 2:TRUNK → Select the bank → :EDCS ID FORM
1:AFS
Display the talkgroup ID in Agency-Fleet-Subfleet (AFS) format.
2:DECIMAL
Display the talkgroup ID in decimal format.
50
Programming APCO 25 Systems
To program an APCO 25 system, follow the steps in the appropriate section for conventional
or Motorola Trunking. APCO 25 systems require only 1 additional setting: Sound Quality.
Setting APCO 25 Sound Quality
Each APCO 25 system has slightly different system settings that control how the audio is
digitized. To get the best sound quality, you need to match as closely as possible the
system’s settings.
To adjust the sound quality:
1. While monitoring a specific APCO P-25 talkgroup, press the ▲/HOLD key.
2. Press and hold the 9 key. On Line 1 of the screen you will see SOUND QULTY:
0050(for example). This shows the Sound Quality. The lower the level the better the
Sound Quality.
3. To manually set the sound quality, rotate the scroll bar up or down. As the threshold
adjusts in increments of 100 at the bottom of the screen watch the Sound Quality level
increase or decrease and continue to rotate the VFO until you have achieved the best
Sound Quality level.
Notes: • When APCO P-25 signal is not received, SOUND QULTY: ****appears
on the display.
• You must be receiving an APCO P-25 signal to make this adjustment
A chart showing the Threshold Adjustment Range is listed below.
Lower
Default
533
633
930
Mid
Default
1985
1985
2147
Upper
Default
3342
3342
3464
Band
800MHz
UHF
Min
33
33
Max
1833
1833
2130
Min
Max
3842
3842
4064
2042
2042
2264
VHF
330
4. Once you have adjusted the Sound Quality to the best possible level, press E.
Press RSM to exit the Sound Quality Adjustment Mode.
.
Notes: • To cancel the adjusted threshold level, press
key.
• The adjusted threshold level for the current frequency can be set back to the
.
default value by pressing and holding the
key.
• When you change the Sound Quality it affects all other APCO 25 signals in that
same band. (UHF, VHF, or 800MHz).
51
Programming LTR Systems
Follow the instructions in this section to program information for LTR trunking systems. For
more information about LTR systems, refer to “Understanding Scanning.”
2:SCAN OPTION → 2:TRUNK → Enter the bank → 1:TRUNK TYPE
1:ON → 9:LT → 2:TRUNK CHANNEL
→
1. Enter the channel number.
1:FREQUENCY
2. Enter the frequency and alpha tag for the channel.
Repeat these steps for all channels in the system. Then, refer to “Programming
Talkgroups.”
Note: LTR systems must be programmed in channel order, skipping unused channels. For
example, if the LTR system you are programming uses only Channels 1, 3, 5, and 7,
program frequencies in the first, third, fifth, and seventh channels in the bank.
52
Programming Talkgroups
For many of the trunk scanning features to operate, you need to program the scanner with
the talkgroup ID’s. Each bank can store up to 100 talkgroups in 10 ID groups of 10
talkgroups each. Group similar talkgroups together in the same ID group. When scanning,
you can turn ID groups on and off with a quick keypress.
Storing Known Talkgroups
Follow these steps to store talkgroups you have gotten from a list.
2:SCAN OPTION → 2:TRUNK → Select the bank → 3:TALK GROUP
1. Use the scroll bar to select the talkgroup to program, then press E.
2. Select 1:ID and press E.
3. For Type 2/Digital systems, enter the up to 5-digit talkgroup ID, then press E.
.
For Type I systems, enter the 3-digit fleet,
for the dash, then the subfleet number.
.
For EDACS systems, enter the two-digit agency,
for the dash, then the fleet and
subfleet number.
For LTR systems, enter the area code,
.
.
, home repeater number,
, ID number,
then E.
Note: If you replace an existing ID, the alpha tag is also deleted.
4. Select 2:ALPHA TAG and press E.
5. Enter the alpha tag for the talkgroup.
Note: The alpha tag defaults to the numeric talkgroup ID.
6. If you want the scanner to beep three times to alert you when the talkgroup is active,
select 3:BEEP ALERT and press E; then, select 1:ON.
7. Press MENU.
Repeat this procedure for each talkgroup in the system.
Storing Found Talkgroups
While you are ID Searching (see “Searching for Active Talkgroups”), you can quickly store
an active talkgroup ID into an ID memory.
1. While the scanner is receiving the talkgroup, press ▲/HOLD to hold on that talkgroup.
2. Press TRNFR. The scanner displays the lowest numbered empty ID group memory.
3. Use the scroll bar to select the memory you want to store the ID into, then press E.
53
Deleting Stored Talkgroup ID’s
To delete a stored talkgroup ID:
1. While scanning a trunked system in the ID scan mode (see “Scanning Only Stored
Talkgroups”), press ▲/HOLD.
Or, to use the menu system:
2:SCAN OPTION → 2:TRUNK → Select the bank → 3:TALK GROUP
2. Use the scroll bar to select the talkgroup ID you want to delete, then press E.
3. Select 1:ID and press E.
4. Press 0, then press E.
Adding a Text Tag to an ID List
To add a text tag to each of the 10 ID lists in each bank:
2:SCAN OPTION → 2:TRUNK → Select the bank → 6:ID LIST TAG
Select the list → Enter the alpha tag
→
Seeing Talkgroup Activity
In the ID Scan mode, the scanner normally only displays the ID for talkgroups that you have
stored into a scan list. This setting lets you see the ID’s for all talkgroups as they become
active when the scanner is monitoring the control channel. The scanner still only switches to
a talkgroup if you have stored it into a scan list.
2:SCAN OPTION → 2:TRUNK → Select the bank → 8:ACTIVITY ID
1:ON
Display every talkgroup ID as it becomes active.
2:OFF
Only display active stored talkgroup ID’s.
54
Using the Remote Interface
You can connect your scanner to either a PC or another BC796D using the remote interface
cable port. This allows you to either control and program your scanner using a PC and the
supplied software and cable or clone the memory from one BC796D into another BC796D
(gender changer/coupler required, not supplied).
PC Control Mode
EXPANSION SLOT
To connect the Scanner to a PC, plug the scanner end of the supplied RS232C cable into
the remote port which is on the side of the scanner. Plug the other end of the cable into your
PC’s serial port.
Start the remote mode and set the scanner’s communications speed:
3:SYSTEM OPTION → 5:PC CONTROL
To use PC control, set the scanner to any setting other than off. You will usually want to set
the speed to its highest setting. If you seem to be having communications problems between
the scanner and PC, set this setting to a lower value.
Cloning Scanner Settings
You will need to purchase an RS232C null modem adapter/gender changer to connect your
scanners together. (These items are available at your local electronics stores.)
To connect the Scanners together, plug the scanner ends of the cables into the scanners,
then connect the PC ends of the cables to the null modem adapter/gender changer
Clone all of the programming of one BC796D into another, by selecting:
3:SYSTEM OPTION → 6:CLONE
on both scanners. Then, on the scanner that has the data you want to transfer, select
MASTER and press E. On the scanner that you want to transfer the data into, select SLAVE
and press E. Then, press SCAN on both scanner to start the transfer.
Caution: This deletes all data from the unit you select as SLAVE. Make certain that you
pick the correct settings for each scanner to prevent data loss.
55
During transfer both scanners display the following.
CLONE
CLONE
== >
MASTER UNIT
== <
SLAVE UNIT
When transfer is complete, the scanners display COMPLETE. Turn both scanners off and
then back on to initialize them.
If data transfer is not successful, the following message appears.
CLONE
ERROR
MASTER UNIT
.
To clear the error, press
. To exit the clone mode, repeatedly press MENU.
56
Care and Maintenance
General Use
• Turn the scanner OFF before disconnecting the power.
• Always write down the programmed frequencies in the event of memory loss.
• If memory is lost, simply reprogram each channel.
The display shows 000.0000 in all channels when there has been a memory loss.
• Always press each button firmly until you hear the entry tone for that key entry, unless you
have turned 2:OFFthe
3:KEY BEEPin the menu system.
Location
• Do not use the scanner in high-moisture environments such as the kitchen or bathroom.
• Avoid placing the unit in direct sunlight or near heating
elements or vents.
• If the scanner receives strong interference or electrical noise, move it or its antenna away
from the source of the noise. If possible, a higher elevation, may provide better reception.
Cleaning
• Disconnect the power to the unit before cleaning.
• Clean the outside of the scanner with a mild detergent.
To prevent scratches, do not use abrasive cleaners or solvents. Be careful not to rub the
LCD window.
• Do not use excessive amounts of water.
Repairs
• Do not attempt any repair. The scanner contains no user serviceable parts. Contact the
Uniden Customer Service Center or take it to a qualified repair technician.
Birdies
• All radios can receive birdies (undesired signals). If your scanner stops during Scan mode
and no sound is heard, it may be receiving a birdie. Birdies are internally generated sig-
nals inherent in the electronics of the receiver.
Press L/O to lockout the channel, and then press RSM to resume scanning.
57
Troubleshooting
If your BC796D is not performing properly, try the following steps.
Problem
Suggestion
Scanner won't work.
1. Check the connections at both ends of the AC Adapter.
2. Turn ON the wall switch of your room. You could be using an outlet
controlled by the wall switch.
3. Move the AC Adapter to another wall outlet.
Improper reception.
Scan won't stop.
1. Check the antenna connection.
2. Move the scanner.
3. You may be in a remote area which could require an optional multi-
band antenna. Check with your dealer or local electronics store.
1. Adjust squelch threshold - refer to page 19, "Setting the Squelch".
2. Check the antenna connection.
3. Check to see if many of the channels are Locked Out.
If so, the scanner has less chance of finding an active channel.
4. Review each channels frequency to see if it is still stored in Memory
and is correct.
5. Its possible that none of the programmed frequencies are currently
active.
Scan won't start.
1. Press the SCAN key again.
2. Adjust squelch threshold - refer to page 19, "Setting the Squelch".
3. Check to see if all channels are Locked Out.
Weather Scan won't work. 1. Adjust squelch threshold - refer to page 19, "Setting the Squelch".
2. Check the antenna.
If you experience difficulty while in TrunkTracker mode, try the following steps.
Problem
Suggestion
1. Missing the Data Frequenc.y
Scanner won't track.
2. Change to a Type 1 Scanner setup.
Review "User Defined Fleet Maps" on page 66.
Scanner won't stop
1. No IDs have been programmed.
during Scan List mode.
2. The IDs you have stored are not active.
Scanner will not acquire 1. Adjust the squelch for Trunking mode.. See page 19.
data channel.
2. Missing the frequency used for the data channel.
Check your frequency list.
Missing replies
1. Change to a Type 1 scanner setup.
to conversations.
Review "User Defined Fleet Maps" on page 66.
2. Try another Preset Fleet Map or Program your own Fleet Map.
3. Check to see that all of the systems frequencies have been entered.
Channel Activity
Indicators are flashing
but no sound is heard.
1. May be a telephone interconnect call, which are intentionally
blocked by your scanner.
2. The ID on your display is not active.
Scanner not tracking
an EDACS system
properly.
1. Logical channel numbers (frequencies) for the system are not
programmed in the correct order.
Check frequency resources and reprogram.
2. Not all frequencies for the system are programmed.
Check frequency resources.
58
Problem
Suggestion
APCO P25 CARD
NOT INSTALLED
appear when the scanner
is turned ON.
1. Check to see if the P-25 Card is properly installed.
Neither APCO P25
CARD INSTALLED
9600 SYSTEMnor
APCO P25 CARD
NOT INSTALLED
appear when the scanner
is turned ON.
1. Check to see if the P-25 Card Mode is 1:ENABLEor
2:DISABLEin the Menu mode.
Scratchy or robotic sound 1. Move to a location where the signal strength is strong.
is heard during
2. Modulation accuracy of transmissions sent can be low.
communications.
Digital communication is
not heard.
1. Verify the accuracy of the frequencies of the P-25 system you
are trying to monitor.
2. You might be in a dead-spot for the P-25 system you are trying
to monitor. Check other locations in the area.
DATA sound is heard at
the beginning of digital
communications.
1. APCO project 25 systems can send data before voice
communication.
2. Data sound can be heard when signal strength is weak.
Robotic sound is heard.
1. Check to see if the ENCmessage appears on the display.
The scanner doesn’t monitor encrypted voice communications.
When CARD ERROR
appears every 10 seconds
while you are using P-25
Card.
1. Re-install the P-25 Card.
If you still cannot get satisfactory results while using your scanner or if you want additional
information, please call or write the Uniden Parts and Service Division. The address and
phone number is listed in the warranty at the end of this manual. If you would like immediate
assistance, please call Customer Service at (800)297-1023.
If you have internet access, you can visit scanner.uniden.com for additional information.
59
Specifications
Certified in accordance with FCC Rules and Regulations Part 15, Subpart C, as of date
of manufacture.
Channel:
1000
Banks:
10 (100 channels each)
Service Bands:
12 preprogrammed search bands
(including the NOAA Weather Service band)
Frequency Range:
25.0-28.0 MHz Petroleum Prod., CB Class D channels,
Business and Forest Products
28.0-29.7 MHz 10 Meter Amateur Band
29.7-50.0 MHz VHF Low Band
50.0-54.0 MHz 6 Meter Amateur Band
54.0-108 MHz
VHF TV, FM broadcast, Intersystem
and Astronomy
108-137 MHz
137-144 MHz
144-148 MHz
148-174 MHz
174-406 MHz
Aircraft Band
Military Land Mobile
2 Meter Amateur Band
VHF High Band
VHF TV, 1.25 Meter Amateur Band, UHF
Aircraft Band
406-420 MHz
420-450 MHz
450-470 MHz
470-512 MHz
806-956 MHz
Federal Government
70 cm Amateur Band
UHF Standard Band
UHF TV Band
800 Band
1240-1300 MHz 25cm Amateur Band
Operating Temperature: –20 °C to +60 °C (-4 °F to +140)
Scan Rate:
100 channels per second (conventional mode)
Search Rate:
100 steps per second (Normal Search)
300 steps per second (Turbo Search)
Audio Output:
Maximum 3.0W (2.3W normal @ 10% THD)
8 ohms (56 mm outer diameter)
Internal Speaker:
Power Requirements: AD580U AC Adapter (13.8V DC, 700mA)
Antenna:
Telescopic Antenna (included)
BNC type
Antenna Jack:
External Jacks:
External Speaker (EXT.SP.) (3.5 mm)
DC 13.8 V Power Jack, (center is positive)
Remote Control (REMOTE) Jack (DB-9)
Tape Recorder Out (TAPE OUT) Jack (3.5 mm)
Digital Card Slot
Size:
6-15/16 in. (W) x 6-9/16 in. (D) x 2-3/8 in. (H)
176.5mm (W) x 167mm (D) x 61mm (H)
1.44 kg (50.8 oz.)
Weight:
Features and specifications are all subject to change without notice.
60
Glossary of Terms
Alpha tag - This term refers to an alphanumeric text tag that you can enter to describe the
individual frequencies that you have programmed. Rather than having to associate a spe-
cific frequency to the individuals that are using it, you can enter the actual name of the
group. This will eliminate the need for memorizing the group’s frequency.
Attenuator - This scanner comes with a feature to attenuate or reduce the signal strength.
The built-in attenuator can be turned on specific frequencies to prevent strong signals from
overloading the scanner input, possibly damaging the scanner or missing other transmis-
sions due to the repeated stopping on the stronger signal.
Clone - This term identifies the ability to set up a duplicate scanner. This function allows
you to clone all the programming information, including frequencies, talkgroups and alpha
tags as well as bank settings and other parameters from one BC796D to another or
BC296D.
Control Channel - This is the frequency within a trunking system that runs the system. On
Control Channels (sometimes called Data Channels) you will hear a buzz saw sound. For
the most part, it is the sound of the system’s central computer directing talkgroups to
particular voice (working) frequencies within the system.
CTCSS - (Continuous Tone Controlled Squelch System) refers to a system where the radio
receivers are equipped with tone responsive devices which allow audio signals to appear
at the audio output, select voice processing such as scrambling or control repeater func-
tions only when a carrier modulated with a specific tone is received. This method may be
used to restrict access to the repeater or receiver, or reduce interference where several
stations with output frequencies in close proximity of each other make it difficult to hear
the conversation you are interested in. With CTCSS squelching, you can eliminate the
possibility of hearing unwanted conversations by selecting one of the 38 standard subaudi-
ble tones. You will only hear those transmissions that have been programmed on specific
frequencies with the specific subaudible tone that you have selected.
DCS - (Digital Controlled Squelch) refers to a system where the radio receivers are
equipped with data burst responsive devices which allow audio signals to appear at the
audio output, select voice processing such as scrambling or control repeater functions only
when a carrier modulated with specific data burst is received. This method may be used to
restrict access to the repeater or receiver, or reduce interference where several stations
with output frequencies in close proximity of each other make it difficult to hear the
conversation you are interested in. With DCS squelching, you can eliminate the possibility
of hearing unwanted conversations by selecting one of the 104 standard data burst
subaudible tones. You will only hear those transmissions that have been programmed on
specific frequencies with the specific subaudible tone that you have selected.
Enter Lock - This is the term used for locking the keypad. This prevents accidental re-pro-
gramming of channels and talkgroups entered into memory. The default setting is OFF.
When ENTER LOCK is enabled, the following functions will be disabled:
• Enter or modify the Memory Channel frequency
• Enter or modify the Tone information
61
• Enter or modify the Trunking ID. ( this can be modified
through the menu screen.)
FIPS Codes - For the purpose of broadcasting weather information, the NWS (National
Weather Service) has divided the United States into regions by state and county (or
parish, where applicable) then assigned a 6 digit FIPS code to identify each county or
parish. The first digit represents the county subdivision, the next two represents the state,
and the last three digits represent the county or parish. Your scanner can receive all
SAME alert signals broadcasted within about a 50-mile radius of where you install it. So if
you only want to hear the counties that are nearest to your area, you can choose
specifically the FIPS code of areas that you want. This lets you avoid hearing warnings
that apply to an area within a 50-mile radius but not necessarily in your county or parish.
I-Call - Most communications within a trunked system are group calls where one unit (such
as a dispatcher) communicates with all the units within her group (all the patrol vehicles on
the east side of town, for example).
The units within this group comprise what is typically known as a talkgroup. There are
some communications which are direct unit-to-unit conversations where one individual
converses with another individual. The call is initiated by a radio and is directed to another
single radio. Within the system, no one outside of these two users hears the conversation.
This call is referred to as I-Call.
Key Beep - This is another term for the tone you hear as a keypad acknowledgement beep.
The default setting is on.
If you have turned the Key Beep off, you now have a silent keypad. You will not hear a
tone each time you press a key.
NWR S.A.M.E. Weather Alert - In 1994, the National Oceanic and Atmospheric
Administration (NOAA) began broadcasting coded signals called FIPS (Federal
Information Processing System) codes along with the standard weather broadcasts for
stations in your area. These codes identify an emergency and the specific geographic
area (such as your county) affected by the emergency. The scanner was developed with
SAME (Specific Area Messaging Encoding) technology.
This allows you scanner to receive, interpret, and display the information about the codes
so you can determine if the emergency might affect you area.Each FIPS code identifies a
specific geographic area (defined by the National Weather Service) so your scanner
sounds an alert only when a weather emergency is declared in those locations.
This helps you more efficiently track the weather conditions in and around your area.
PC Control - This term is associated with the ability to program frequencies and other
useful information via a computer by means of third party software. You can change the
transfer speed on the scanner needed to be compatible with your PC. (See page 55)
Scan List - When you designate a bank to be a trunking bank, your scanner sets up 10
Scan Lists, which are simply list of your favorite IDs. Each list can contain up to 10 IDs, so
you can store a total of 100 IDs for each trunk bank. These lists are designed to help you
organize the trunking system users into categories.
Screen Mask - Screen Mask reduces the amount of information that appears on the
display. Alpha tags that you have set for a channel along with a few function icons will
appear only on the display. This mode is particularly useful in public safety vehicles where
that are already overloaded with information. Screen Mask does not work in Search mode.
62
Status Bit - This term refers to Motorola Type II systems. There is a method by which
special types of communications utilize unique talk group numbers.
For example, if all emergency calls are set to occur on a specific talk group number then
you will not miss the transmission even if you have not programmed all the talk group
numbers. With the Status Bit on and you have programmed the unique number, then you
don’t have to worry what the rest of the groups numbers are. The topic of interest will be
picked up.
Talkgroup - A group of users within a trunked system that communicates with one another.
63
Appendix
Preset Fleet Maps
Preset Map 1
Preset Map 2
Block
Size Code
Block
Size Code
0
1
2
3
4
5
6
7
SIZE CODE 11
SIZE CODE 11
SIZE CODE 11
SIZE CODE 11
SIZE CODE 11
SIZE CODE 11
SIZE CODE 11
SIZE CODE 11
0
1
2
3
4
5
6
7
SIZE CODE 4
SIZE CODE 4
SIZE CODE 4
SIZE CODE 4
SIZE CODE 4
SIZE CODE 4
SIZE CODE 4
SIZE CODE 4
Preset Map 3
Preset Map 4
Block
Size Code
SIZE CODE 4
SIZE CODE 4
SIZE CODE 4
SIZE CODE 4
SIZE CODE 4
SIZE CODE 4
SIZE CODE 12
(SIZE CODE 12)
Block
Size Code
SIZE CODE 12
(SIZE CODE 12)
SIZE CODE 4
SIZE CODE 4
SIZE CODE 4
SIZE CODE 4
SIZE CODE 4
SIZE CODE 4
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
Preset Map 5
Preset Map 6
Block
Size Code
SIZE CODE 4
SIZE CODE 4
SIZE CODE 12
(SIZE CODE 12)
SIZE CODE 4
SIZE CODE 4
SIZE CODE 4
SIZE CODE 4
Block
Size Code
SIZE CODE 3
SIZE CODE 10
SIZE CODE 4
SIZE CODE 4
SIZE CODE 12
(SIZE CODE 12)
SIZE CODE 12
(SIZE CODE 12)
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
Preset Map 7
Preset Map 8
Block
Size Code
SIZE CODE 10
SIZE CODE 10
SIZE CODE 11
SIZE CODE 4
SIZE CODE 4
SIZE CODE 4
SIZE CODE 4
SIZE CODE 4
Block
Size Code
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
SIZE CODE 1
SIZE CODE 1
SIZE CODE 2
SIZE CODE 2
SIZE CODE 3
SIZE CODE 3
SIZE CODE 4
SIZE CODE 4
64
Preset Map 9
Preset Map 10
Block
Size Code
Block
Size Code
0
1
2
3
4
5
6
7
SIZE CODE 4
SIZE CODE 4
SIZE CODE 0
SIZE CODE 0
SIZE CODE 0
SIZE CODE 0
SIZE CODE 0
SIZE CODE 0
0
1
2
3
4
5
6
7
SIZE CODE 0
SIZE CODE 0
SIZE CODE 0
SIZE CODE 0
SIZE CODE 0
SIZE CODE 0
SIZE CODE 4
SIZE CODE 4
Preset Map 11
Preset Map 12
Block
Size Code
Block
Size Code
0
1
2
3
4
5
6
7
SIZE CODE 4
SIZE CODE 0
SIZE CODE 0
SIZE CODE 0
SIZE CODE 0
SIZE CODE 0
SIZE CODE 0
SIZE CODE 0
0
1
2
3
4
5
6
7
SIZE CODE 0
SIZE CODE 0
SIZE CODE 0
SIZE CODE 0
SIZE CODE 0
SIZE CODE 0
SIZE CODE 0
SIZE CODE 4
Preset Map 13
Preset Map 14
Block
Size Code
SIZE CODE 3
SIZE CODE 3
SIZE CODE 11
SIZE CODE 4
SIZE CODE 4
SIZE CODE 0
SIZE CODE 0
SIZE CODE 0
Block
0
1
2
3
4
5
6
7
Size Code
SIZE CODE 4
SIZE CODE 3
SIZE CODE 10
SIZE CODE 4
SIZE CODE 4
SIZE CODE 4
SIZE CODE 12
(SIZE CODE 12)
0
1
2
3
4
5
6
7
Preset Map 15
Preset Map 16
Block
Size Code
SIZE CODE 4
SIZE CODE 4
SIZE CODE 4
SIZE CODE 11
SIZE CODE 11
SIZE CODE 0
SIZE CODE 12
(SIZE CODE 12)
Block
Size Code
SIZE CODE 3
SIZE CODE 10
SIZE CODE 10
SIZE CODE 11
SIZE CODE 0
SIZE CODE 0
SIZE CODE 12
(SIZE CODE 12)
0
1
2
3
4
5
6
0
1
2
3
4
5
6
7
7
65
User Defined Fleet Maps
Type I Programming Information
When a Type I system is designed, the address information for all the IDs are divided into 8
equal sized blocks. When you program your scanner to track a Type I system, you must
select a size code for each of these blocks. When you have assigned a size code to all 8
blocks, you have defined the Fleet Map for the system you're tracking. Each size code
determines the number of Fleets, Subfleets, and IDs each block will have. For example, a
size code of "4" has one Fleet, which is divided into 16 separate Subfleets, and it has a total
of 512 individual IDs.
When a block is assigned a size code, the Fleet or Fleets created within the block are
assigned a Type I ID. The way these IDs display on your scanner depends on the block
number and the blocks size code. When a Type I ID displays, the left most digit represents
the block which contains the ID. The next two or three digits identify which Fleet is active,
and the last digit(s) identifies the Subfleet.
Block
(1 digit)
Subfleet
(1 or 2 digits)
Which Fleet
within the Block
(2 or 3 digits)
The details concerning how the size codes are selected by a Type I system designer are
highly dependent on the specific needs of the systems users. Some organizations may want
many subfleets with only a few radios each, while another organization may want only a few
subfleets with many radios each. Your task is to program your fleet map with the same size
code assignments as the trunked system. If you do this accurately, you'll track all the Fleet-
Subfleet combinations used by the system. In other words, you'll hear complete
communications while monitoring a trunked system.
If you don't already know the size codes used, you'll have to guess at them. But since you
don't have to figure out all the blocks at once, this isn't as hard as it seems. Select a size
code for a block, and then press SCAN. Now listen to the communications. If you decide you
are receiving most of the replies to the conversations with IDs assigned to the block you just
programmed, then you've probably selected the right size code and can work on the next
block of the map.
Finally, for most public safety systems there are some size codes which are more common.
SIZE CODE 3 and SIZE CODE 4 are probably the most common, followed by SIZE CODE
10, SIZE CODE 11, and SIZE CODE 12.
66
Fleet Map Size Codes
Blocks
Used
Size
Fleets
Subfleets
IDs
0
1
Reserves block for Type II IDs
+
1
1
1
1
1
1
1
1
1
1
1
2
4
8
128
16
8
4
8
16
64
2
3
8
128
512
32
4
1
16
4
5
64
32
32
16
8
6
8
32
7
4
64
8
4
128
256
256
256
1024
2048
4096
9
4
10
11
12
13
14
4
8
2
16
16
16
16
1
1
1
Size Code Restrictions
If you select SIZE CODE 12, 13, or 14, there are some restrictions as to which blocks can
be used for these codes.
• SIZE CODE 12 can only be assigned to Blocks 0, 2, 4, or 6.
• SIZE CODE 13 can only be assigned to Blocks 0 and 4.
• SIZE CODE 14 can only be assigned to Block 0.
Since these SIZE CODES require multiple blocks, you will be prompted for the next
available block when programming a Fleet Map. For example, if you assign Block 0 as an
SIZE CODE 12, you will be prompted for Block 2, the next block available, instead of Block
1. And if you assign Block 0 as SIZE CODE 14, you would not see another prompt because
all available blocks have been used.
67
NWR-SAME EVENT CODE
Event Code
Standard
Event Level (Siren Type)
LCD Display
Warning
Watch
Statement
Test
Emergency Action Notification
Emergency Action Termination
National Information Center
Tornado Warning #
Service Thunderstorm Warning # SVW(or SVR)
Flash Flood Warning
Flash Warning
Winter Storm Warning
Blizzard Warning
High Wing/ Dust Storm Warning
Radio logical Hazard Warning
Civil Danger Warning
Local Area Emergency
Hazardous Material Warning
Civil Emergency Message
Immediate Evacuation Warning
Immediate Evacuation Notice
Law Enforcement Warning
Fire Warning
EAN
EAT
NIC
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
EMG NOTIFY
EMG TERMINATE
NATIONAL INFO
TORNADO
THUNDERSTORM
FLASH FLOOD
FLOOD
WINTER STORM
BLIZZARD
HIGH WIND
RADIOLOGICAL
CIVIL DANGER
LOCAL EMG
HAZARDOUS
CIVIL EMG
EVACUATION
EVACUATE NOTE
LAW ENFORCEMENT
FIRE
TOW(or TOR)
FFW
FLW
WSW
BZW
HWW
RHW
CDW
LAE
HMW
CEM
IEW
EVI
LEW
FRW
Hurricane/Tropical Storm Warning HUW
Tsunami Warning
HURRICANE
TSUNAMI
COASTAL FLOOD
SPECIAL MARINE
AVALANCHE
VOLCANO
TSW
CFW
SMW
AVW
VOW
SPW
CDA
RHA
HMA
WSA
HWA
TOA
SVA
FFA
Coastal Flood Warning
Special Marine Warning
Avalanche Warning
Volcano Warning
Shelter In Place Warning
Civil Danger Watch
Radiological Hazard Watch
Hazardous Material Watch
Winter Storm Watch
High Wind/ Dust Storm Watch
Tornado Watch
Severe Thunderstorm Watch
Flash Flood Watch
Flood Watch
Hurricane/ Tropical Storm Watch
Tsunami Watch
Coastal Flood Watch
Avalanche Watch
SHELTER
0
0
0
0
0
0
0
0
0
0
0
0
0
0
CIVIL DANGER
RADIOLOGICAL
HAZARDOUS
WINTER STORM
HIGH WIND
TORNADO
THUNDERSTORM
FLASH FLOOD
FLOOD
HURRICANE
TSUNAMI
COASTAL FLOOD
AVALANCHE
VOLCANO
FLA
HUA
TSA
CFA
AVA
VOA
Volcano Watch
68
Event Level (Siren Type)
Event Code
Standard
LCD Display
Warning
Watch
Statement
Test
Severe Weather Statement
Special Weather Statement
Flash Flood Statement
Flood Statement
Hurricane Statement
National Periodic Test
Required Monthly Test
Required Weekly Test
System Demonstration/ Practice
National Hazard Warning
Unknown Emergency Tune TV
Unknown Warning Tune TV
Unknown Watch Tune TV
Unknown Statement Tune TV
Administrative Message
Child Abduction Emergency
Dusd Storm Warning
SVS
SPS
FFS
FLS
HLS
NPT
RMT
RWT
DMO
NHW
**E
0
0
0
0
0
SEVERE WX
SPECIAL WX
FLASH FLOOD
FLOOD
HURRICANE
NATION PERIOD
MONTHLY
WEEKLY
SYSTEM DEMO
NATION HAZARD
UNKNOWN TV
UNKNOWN TV
UNKNOWN TV
UNKNOWN TV
ADMIN MESSAGE
CHILD EMERGENCY
DUST STORM
EARTHQUAKE
NETWORK MESSAGE
911 PHONE OUTAGE
NUCLEAR PLANT
TROPICAL STORM
TROPICAL STORM
DUST STORM
0
0
0
Note
0
0
0
**W
**A
**S
0
0
0
ADR
CAE
DSW
EQW
NMN
TOE
NUW
TRW
TRA
DSA
EQA
MIS
NPM
NPW
NPP
SCS
DBW
0
0
Earthquake Warning
0
Network Message Notification
911 telephone Outage Emergency
Nuclear Power Plant Warning
Tropical Storm Warning
Tropical Storm Watch
0
0
0
0
0
0
0
Dust Storm Watch
Earthquake Watch
EATHQUAKE
Missing Child Statement
Nuclear Power Plant Test Messag
Nuclear Power Plant Warning
Nuclear Power Plant Warning
School Closing Statement
Dam Break Warning
0
0
MISSING CHILD
NUCLEAR PLANT
NUCLEAR PLANT
NUCLEAR PLANT
SCHOOL CLOSING
DAM BREAK
0
0
0
0
Note: Demo alerts are displayed but no audible alert is generated.
69
REVERSE LIST
Range
Offset
+0.1 MHz
-0.1 MHz
+1 MHz
Range
Offset
-5 MHz
+5 MHz
-5 MHz
+5 MHz
-5 MHz
+3 MHz
-3 MHz
+3 MHz
-3 MHz
+3 MHz
-3 MHz
+3 MHz
-3 MHz
+3 MHz
-3 MHz
+3 MHz
-3 MHz
+3 MHz
-3 MHz
+45 MHz
-45 MHz
+39 MHz
-39 MHz
29.520 - 29.580
29.620 - 29.680
52.010 - 52.990
53.010 - 53.990
143.750
445.000 - 449.9875
450.000 - 454.9875
455.000 - 459.9875
460.000 - 464.9875
465.000 - 469.9875
470.000 - 472.9875
473.000 - 475.9875
476.000 - 478.9875
479.000 - 481.9875
482.000 - 484.9875
485.000 - 487.9875
488.000 - 490.9875
491.000 - 493.9875
494.000 - 496.9875
497.000 - 499.9875
500.000 - 502.9875
503.000 - 505.9875
506.000 - 508.9875
509.000 - 511.9875
806.000 - 823.9875
851.000 - 868.9875
896.000 - 901.000
935.000 - 940.000
-1 MHz
+4.375 MHz
+4.25 MHz
+0.6 MHz
-0.6 MHz
+0.6 MHz
+1 MHz
143.900
144.510 - 144.890
145.110 - 145.490
146.010 - 146.385
146.415 - 146.505
146.595
146.610 - 146.985
147.000 - 147.390
147.415 - 147.505
147.595
+1 MHz
-0.6 MHz
+0.6 MHz
-1 MHz
-1 MHz
147.600 - 147.990
148.125
-0.6 MHz
-4.375 MHz
-4.25 MHz
+1.6 MHz
-1.6 MHz
+5 MHz
148.150
222.120 - 223.380
223.720 - 224.980
420.000 - 424.9875
425.000 - 429.9875
440.000 - 444.9875
-5 MHz
+5 MHz
The reverse frequency for trunked systems is determined by the trunking system settings
and can vary from the standard band plans.
CTCSS Frequency List (Hz)
67.0
91.5
71.9
94.8
74.4
77.0
79.7
82.5
85.4
88.5
97.4 100.0 103.5 107.2 110.9 114.8
118.8 123.0 127.3 131.8 136.5 141.3 146.2 151.4
156.7 162.2 167.9 173.8 179.9 186.2 192.8 203.5
210.7 218.1 225.7 233.6 241.8 250.3
DCS Tone Code
023
051
114
143
174
245
266
332
411
452
506
612
703
025
053
115
145
205
246
271
343
412
454
516
624
712
026
054
116
152
212
251
274
346
413
455
523
627
723
031
065
122
155
223
252
306
351
423
462
526
631
731
032
071
125
156
225
255
311
356
431
464
532
632
732
036
072
131
162
226
261
315
364
432
465
546
654
734
043
073
132
165
243
263
325
365
445
466
565
662
743
047
074
134
172
244
265
331
371
446
503
606
664
754
70
BC796D Flow Charts
71
72
73
One Year Limited Warranty
Important: Evidence of original purchase is required for warranty service.
WARRANTOR: UNIDEN AMERICA CORPORATION (Uniden)
ELEMENTS OF WARRANTY: Uniden warrants, for one year, to the original retail owner, this Uniden
product to be free from defects in materials and craftsmanship with only the limitations or exclusions set
out below.
WARRANTY DURATION: This warranty to the original user shall terminate and be of no further effect
12 months after the date of original retail sale. The warranty is invalid if the Product is (A) damaged or
not maintained as reasonable or necessary, (B) modified, altered, or used as part of any conversion kits,
subassemblies, or any configurations not sold by Uniden, (C) improperly installed, (D) serviced or
repaired by someone other than an authorized Uniden service center for a defect or malfunction
covered by this warranty, (E) used in any conjunction with equipment or parts or as part of any system
not manufactured by Uniden, or (F) installed or programmed by anyone other than as detailed by the
owners manual for this product.
STATEMENT OF REMEDY: In the event that the product does not conform to this warranty at any time
while this warranty is in effect, warrantor will either, at its option, repair or replace the defective unit and
return it to you without charge for parts, service, or any other cost (except shipping and handling)
incurred by warrantor or its representatives in connection with the performance of this warranty.
Warrantor, at its option, may replace the unit with a new or refurbished unit. THE LIMITED WARRANTY
SET FORTH ABOVE IS THE SOLE AND ENTIRE WARRANTY PERTAINING TO THE PRODUCT AND
IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES OF ANY NATURE WHATSOEVER,
WHETHER EXPRESS, IMPLIED OR ARISING BY OPERATION OF LAW INCLUDING, BUT NOT
LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. THIS WARRANTY DOES NOT COVER OR PROVIDE FOR THE
REIMBURSEMENT OR PAYMENT OF INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states
do not allow this exclusion or limitation of incidental or consequential damages so the above limitation or
exclusion may not apply to you.
LEGAL REMEDIES: This warranty gives you specific legal rights, and you may also have other rights
which vary from state to state. This warranty is void outside the United States of America.
PROCEDURE FOR OBTAINING PERFORMANCE OF WARRANTY: If, after following the instructions
in the owners manual you are certain that the product is defective, pack the Product carefully (preferably
in its original packaging). The product should include all parts and accessories originally packaged with
the Product. Include evidence of original purchase and a note describing the defect that has caused you
to return it. The Product should be shipped freight prepaid, by traceable means, to warrantor at:
UNIDEN AMERICA CORPORATION
Parts and Service Division
4700 Amon Carter Boulevard
Fort Worth, TX 76155
(800) 554-3988, 7 a.m. to 5 p.m. Central Time, Monday through Friday
74
Memo
75
Memo
76
Memo
77
|